Electrical Specifications - Fluke 373 User Manual

Clamp meter
Hide thumbs Also See for 373:
Table of Contents

Advertisement

Clamp Meter
The Meter

Electrical Specifications

AC Current
Range .....................................................600.0 A
Resolution ...............................................0.1 A
Accuracy .................................................2 % ± 5 digits (48 – 62 Hz)
Crest Factor (50/60 Hz) ..........................2.5 @ 600 A
AC Voltage
Range ....................................................600.0 V
Resolution ...............................................0.1 V
Accuracy .................................................1.0 % ± 5 digits (48 – 62 Hz)
DC Voltage
Range ....................................................600.0 V
Resolution ...............................................0.1 V
Accuracy .................................................1 % ± 5 digits
Resistance
Range .....................................................600.0 Ω/6000 Ω
Resolution ...............................................0.1 Ω/1 Ω