Maintenance Instructions; Combustion In Air Adjustment - Napoleon BIG32 Owner's Manual

Hide thumbs Also See for BIG32:
Table of Contents

Advertisement

Maintenance Instructions

RECOMMENDATIONS
This grill should be thoroughly inspected and serviced annually by a qualified service person.
• Do not obstruct the flow of ventilation and combustion air.
• Keep the cylinder enclosure ventilation openings located on the side of the cart or enclosure and front and back of the
bottom shelf clear from debris.
WARNING! Keep the grill away from combustible materials, gasoline, and other flammable vapors and liquids.
c
omBuStion in air adjuStment
!
IMPORTANT! This must be done by a qualified gas installer.
• The air shutter is factory set and should not require adjusting under
normal conditions. Adjustments might be required under extreme field
conditions.
• The flames of the air shutter will be dark blue, tipped with light blue and
occasionally yellow when adjusted correctly.
• Too little air flow to the burner will produce soot and lazy yellow flames.
• Too much air flow to the burner will cause flames to lift erratically and
cause igniting difficulties.
Adjusting the Air Shutter
1. Remove cooking grids and sear plates. Leave lid open.
2. You may have to open the cabinet door or remove the top drawer (if
equipped) to access the air shutter screw located at the mouth of the
burner.
3. Remove the back cover to adjust rear tube burner air shutter.
4. Loosen air shutter lock screw and open or close air shutter as required.
(Fig. 1)
5. Light the burners on high.
6. Visually inspect burner flames.
7. Turn burners off, tighten locking screws, and replace removed parts when
shutters are set correctly.
8. Ensure insect screens are installed.
Note: Infrared burners have no air adjustment.
WE WANT
TO HELP!
Contact the Napoleon
Customer Solutions
Department for
recommended
replacement parts.
1-866-820-8686.
20
| Maintenance
Main Burner
Model
Propane
BIG 32
Natural gas
Propane
BIG 38
Natural gas
Propane
BIG 44
Natural gas
Propane
BIB 10 RT
Natural gas
Propane
BIB 10 IR
Natural gas
Propane
BIB 18 RT
Natural gas
Propane
BIB 18 IR
Natural gas
Light Blue
Dark Blue
Burner Port
Orifice Size
Rear Burner
Main Burner
#60
1.25mm
1.45mm
#50
3/8"
#60
1.25mm
1.45mm
#50
3/8"
#60
1.25mm
1.45mm
#50
3/8"
#64
-
#55
-
#64
-
1.27mm
-
1.2mm
-
1.7mm
-
1.15mm
-
#52
-
Napoleon.com | BUILT-IN Series
!
Yellow Tip
Air Shutter
Rear Burner
1/2"
Full
Full
1/2"
Full
Full
1/2"
Full
Full
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Fig. 1

Advertisement

Table of Contents
loading

Table of Contents