Wiring an Isolated Output to an External Load

Caution
Do not draw more than 100 mA from 24 V or 30 V isolated outputs. Do not draw
more than 50 mA from 5 V isolated outputs.
© National Instruments Corporation
The digital output circuit sources current to external loads, as shown in
the example in Figure 3-6.
V
cc
NI CVS-1450 device
Figure 3-6. Example of Connecting an Isolated Output to an External Load
3-13
Chapter 3
Digital I/O Functionality
Digital Output
Load
C
iso
NI CVS-1450 Series User Manual
V
iso