Problem Areas
1.15 Compass
1.15.1 Compass fails
Check:
Inspect the BtB connector of Main FPC Assy to Main PBA.
Action:
1. If not properly connected – disconnect and reconnect it.
2. If dirty or oxidized – clean it.
3. If the FPC of Main FPC Assy is damaged – replace the
Main FPC Assy.
Check:
Inspect the compass chip on the Main FPC Assy.
Action:
1. If the compass chip is damaged – replace the Main FPC
Assy.
2. Replace Main PBA.
1290-1679 Rev 3
©
Sony Mobile Communications AB – Company Internal
Troubleshooting Guide (mech)
34(58)