Whirlpool WMH53521HZ Installation Instructions Manual page 13

Hide thumbs Also See for WMH53521HZ:
Table of Contents

Advertisement

Recommended Vent Length
1
A 3
" x 10" (8.3 x 25.4 cm) rectangular or 6" (15.2 cm) round
4
vent should be used.
The total length of the vent system including straight vent,
elbow(s), transitions and wall or roof caps must not exceed
the equivalent of 140 ft (42.7 m) for either type of vent. See
the "Recommended Standard Fittings" section for equivalent
lengths.
For best performance, use no more than three 90° elbows.
To calculate the length of the system you need, add the
equivalent lengths of each vent piece used in the system.
See the following examples:
1
3
" x 10" (8.3 x 25.4 cm) vent system = 73 ft (22.2 m)
4
total
A
2 ft
(0.6 m)
1
3
"
A. One
x 10" (8.3 x 25.4 cm) 90° elbow = 25 ft (7.6 m)
4
B. One wall cap = 40 ft (12.2 m)
C. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)
B
6 ft (1.8 m)
C
6" (15.2 cm) vent system = 73 ft (22.2 m) total
A
2 ft
(0.6 m)
C
A. Two 90° elbows = 20 ft (6.1 m)
B. One wall cap = 40 ft (12.2 m)
C. One rectangular-to-round transition piece = 5 ft (1.5 m)
D. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)
If the existing vent is round, a rectangular to round transition
piece must be used. In addition, a rectangular 3" (7.6 cm)
extension vent between the damper assembly and rectangular to
round transition piece must be installed to keep the damper from
sticking.
B
6 ft (1.8 m)
D
13