3.4

I/O Signal List

The following shows the list of the A/D converter module I/O signals.
For the details of I/O signals, refer to the followings.
• Details of I/O signals (
Input signal
Device number
X0
Module READY
X1
X2
X3
X4
Use prohibited
X5
X6
X7
X8
Warning output signal
X9
Operating condition setting completed flag
XA
Offset/gain setting mode flag
XB
Channel change completed flag
XC
Input signal error detection signal
Maximum value/minimum value reset
XD
completed flag
XE
A/D conversion completed flag
XF
Error occurrence flag
The I/O number (X/Y) described above shows the case that the start I/O number of the A/D converter module is set to "0".
Page 95, Appendix 1)
Signal name
Output signal
Device number
Y0
Y1
Y2
Y3
Y4
Use prohibited
Y5
Y6
Y7
Y8
Y9
Operating condition setting request
YA
User range write request
YB
Channel change request
YC
Use prohibited
Maximum value/minimum value reset
YD
request
YE
Use prohibited
YF
Error clear request
CHAPTER 3 SPECIFICATIONS
Signal name
23