Download Print this page

Oregon Scientific BAR686A User Manual page 2

Wireless weather forecaster with temperature display and self - setting atomic clock

Advertisement

TEMPERATURE
To toggle temperature unit:
Press °C / °F.
To view outdoor sensors
temperature
readings:
Press CHANNEL.
To auto-scan between sensors:
Press and hold CHANNEL for 2 seconds. Each sensor's
data is displayed for 3 seconds.
To end auto-scan:
Press CHANNEL or MEM.
To toggle between current, minimum and maximum
records for the selected sensor:
Press MEM repeatedly.
To clear the records:
Press and hold MEM for 2 seconds.
TEMPERATURE AND PRESSURE TREND
The temperature and pressure trend icons are based on
recent sensor readings.
RISING
STEADY
FALLING
ICE WARNING
If the channel 1 sensor falls between 3°C to –2°C (37°F
to 28°F),
flashes to warn you that the temperature is
approaching freezing.
NOTE The warning will automatically stop if the temperature
goes outside the ice-warning range.
HI / LO TEMPERATURE ALARM
An alert can be set to sound if the sensor set to channel 1
records above or below a temperature of your choice.
To set alarm ON/OFF:
1. Press and hold TEMP HI / LO
.
2. Use
and
to select high / low temperature alarm.
Press TEMP HI / LO
to confirm.
3. Press
/
to set alarm ON / OFF and press TEMP
HI / LO
to confirm.
4. If alarm has been activated, use
and
to select
the temperature.
5. Press TEMP HI / LO
to confirm.
To silence the hi / lo temperature alarm:
Press any key. The alarm resets automatically and will
resound if the hi / lo temperature selected is recorded
again.
MOON PHASE
• When calendar is set press
or
to view the moon
phase for the next/previous day.
• Press and hold
or
to scan through the years
(2001 to 2099).
New Moon
Waxing Crescent
First quarter
Waxing Gibbous
Full Moon
Waning Gibbous
Last quarter
Waning Crescent
RESET
Press RESET to return the unit to the default settings.
PRECAUTIONS
This product is engineered to give you years of
satisfactory service if you handle it carefully. Here are a
few precautions:
• Do not subject the unit to excessive force, shock,
dust, temperature or humidity, which may result in
malfunction, shorter electronic life span, damaged
battery and distorted parts.
• Do not immerse the unit in water. If you spill liquid over
it, dry it immediately with a soft, lint-free cloth.
BAR686_M
• Do not clean the unit with abrasive or corrosive
materials.
• Do not tamper with the unit's internal components.
Doing so will invalidate the warranty on the unit and
may cause unnecessary damage. The unit contains no
user-serviceable parts.
• Only use fresh batteries as specified in the user's
instructions. Do not mix new and old batteries.
• Due to printing limitations, the displays shown in this
manual may differ from the actual display.
• The contents of this manual may not be reproduced
without the permission of the manufacturer.
NOTE The technical specifications for this product and
the contents of the user manual are subject to change
without notice.
SPECIFICATIONS
TYPE
DESCRIPTION
MAIN UNIT
L x W x H
77 x 126 x 102 mm
(3.14 x 5.14 x 4.16 in)
Weight
183 g (6.46 oz) without batteries
Temperature
unit
°C / °F
Temperature range
-5°C to 50°C (23°F to 122°F)
Resolution
0.1°C (0.2°F)
Clock frequency
WWVB-60 (US)
Synchronization
Auto or disabled
Signal frequency
433 MHz
Clock
Auto or manual (disabled)
Humidity range
25% - 95%
Humidity resolution 1%
Memory
Min / Max relative humidity and
temperature
Alarm duration
2 minutes
Snooze
8 minutes
Clock display
HH:MM:SS
HH:MM: Day of Week
Hour format
12 / 24 hour format
Calendar
MM / DD or DD / MM
language selectable:
E, F, D, I and S
Power
3 x UM-3 (AA) 1.5 V batteries
REMOTE UNIT
L x W x H
92 x 60 x 20 mm
(3.6 x 2.4 x 0.8 in)
Weight
62 g (2.22 ounces)
without battery
Transmission range
30 m (100 ft) unobstructed
Temperature Range
-30°C to 60°C
(-22°F to 140°F)
Power
2 x UM-4 (AAA) 1.5 V batteries
NOTE We recommend that you use alkaline batteries
with this product for longer usage and lithium batteries in
temperatures below freezing.
ABOUT OREGON SCIENTIFIC
Visit our website (www.oregonscientific.com) to learn more
about Oregon Scientific products such as digital cameras;
MP3 players; children's electronic learning products and
games; projection clocks; health and fitness gear; weather
stations; and digital and conference phones. The website
also includes contact information for our Customer Care
department in case you need to reach us, as well as fre-
quently asked questions and customer downloads.
We hope you will find all the information you need on our
website, however if you're in the US and would like to
contact the Oregon Scientific Customer Care department
directly, please visit:
www2.oregonscientific.com/service/default.asp
OR
Call 1-800-853-8883.
For international inquiries, please visit:
www2.oregonscientific.com/about/international.asp
2
FCC STATEMENT
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) This
device must accept any interference received, including
interference that may cause undesired operation.
WARNING Changes or modifications not expressly
approved by the party responsible for compliance could
void the user's authority to operate the equipment.
NOTE This equipment has been tested and found to
comply with the limits for a Class B digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference
in a residential installation.
This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there
is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be
determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or
more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment
and receiver.
Connect the equipment into an outlet on a circuit
different from that to which the receiver is
connected.
Consult the dealer or an experienced radio / TV
technician for help.
DECLARATION OF CONFORMITY
The following information is not to be used as contact for
support or sales. Please call our customer service number
(listed on our website at www.oregonscientific.com), or
on the warranty card for this product) for all inquiries
instead.
We
Name:
Oregon Scientific, Inc.
Address:
19861 SW 95th Ave.,Tualatin,
Oregon 97062 USA
Telephone No.:
1-800-853-8883
declare that the product
Product No.:
BAR686A
Product Name:
Wireless Weather Forecaster
with Temperature Display and
Self - Setting Atomic Clock
Manufacturer:
IDT Technology Limited
Address:
Block C, 9/F, Kaiser Estate,
Phase 1,41 Man Yue St.,
Hung Hom, Kowloon,
Hong Kong
is in conformity with Part 15 of the FCC Rules. Operation
is subject to the following two conditions: 1) This device
may not cause harmful interference. 2) This device must
accept any interference received, including interference
that may cause undesired operation.
2005.12.2, 2:31 PM
© 2006 Oregon Scientific. All rights reserved.
P/N: 086L004258-017

Advertisement