SWR SWP-ASR300 Series Manual

Windows debugger for the st7 emulator, simulator and development kit

Advertisement

Quick Links

P
a
p
e
r
l
P
a
p
e
r
l
香 港
港 昌
昌 晖
晖 自
C
H
A
R
M
F
C
H
A
R
M
F
C
H
A
R
M
F
Swp
Charm Faith instrument copyright.
5~~
Charm Faith Autosystem Instrument
S
W
P
-
A
S
S
W
P
-
A
S
e
s
s
r
e
c
o
e
s
s
r
e
c
o
m
a
n
m
a
n
自 动
动 化
化 系
A
I
T
H
A
U
T
A
I
T
H
A
U
T
A
I
T
H
A
U
®
is CharmFaith Autosystem trade mark.
R
s
e
r
i
e
s
R
s
e
r
i
e
s
r
d
e
r
O
p
r
d
e
r
O
p
u
a
l
u
a
l
系 统
统 有
有 限
O
S
Y
S
T
E
M
O
S
Y
S
T
E
M
T
O
S
Y
S
T
E
M
e
r
a
t
i
n
g
e
r
a
t
i
n
g
限 公
公 司
C
O
.
,
L
T
D
.
C
O
.
,
L
T
D
.
C
O
.
,
L
T
D
.
- 1 -

Advertisement

loading

Summary of Contents for SWR SWP-ASR300 Series

  • Page 1 Charm Faith Autosystem Instrument 香 港 昌 晖 自 动 化 系 统 有 限 公 司 香 港 港 昌 昌 晖 晖 自 自 动 动 化 化 系 系 统 统 有 有 限 限 公 公 司 司...
  • Page 2 Shipping detail Dear customer, Appreciate you use Charm Faith SWP-ASR300 series paperless recorder. Please check the shipping items included. Any issue, please contact our service center or distributor. We will great to provide our best service! Shipping items SWP-ASR300 paperless recorder SWP-ASR300 user manual Installation fixing Power filter modutor...
  • Page 3 1.ART RECORDER ..................... - 5 - FEATURES ....................- 5 - DATA SAVING MODE ................- 7 - g ..................- 7 - g ....................- 7 - ALARM ....................- 7 - ) ......- 7 - s ....................- 8 - s ....................
  • Page 4 m ........................ - 18 - g ..................- 18 - k ......................- 19 - ..............- 19 - N ................. - 20 - 4.1 T ......................- 20 - REND ..................- 22 - ....................- 22 - ....................- 22 - ....................
  • Page 5 1.art Recorder 1.1 Features 1.1.1 Input & Output T.C: B、S、K、E、T、J、W Analog Input RTD: PT100、CU50 DC: 0-5V, 1-5V, 0-100mV, 0-20mV, 4-20mA Input signal Top of Form Pulse Input Rectangular, sine or triangular wave: Amplidute Range>= 4V, frequency 0 - 15KHz Bottom of Form DC Current: 0-10mA, 4-20mA Analog output DC Voltage: 0-5V, 1-5V...
  • Page 6 1.1.3 Capacity (Mbit) Interrecord time (S) Channel Number Approx recording date (Default 16401 configuration) 8200 4100 1984 1594 38037 (Extened) 19134 9567 4629 3415 1705 82005 (Extend) 41000 20500 9920 e :  Input Mode Measuring range Input Mode Measuring range 0~20mV -9999~99999 -50.
  • Page 7 1.2 Data saving mode Nand Flash is used in the recorder. No battery is needed. It is safety for power incidently failure.) No distortion from recordered data as the data was saved as 16 bits. Figure 1-2-1 1 minute (1 pix) 30 minuts (30 pixes) Figure 1-2-1 Normal U drive (2.0 versions) is used for data transferring.
  • Page 8 Lower limit: LED turns to red and “L” mark is display besides real time value Alarm output ON when alarm activated. It will return to green and “L” mark disappears after alarm Hysteresis Alarm value relieving. Measured value Figure 1-3-2 Rate-of-change upper limit Measured value When the rising rate of change is great to...
  • Page 9: Installation And Wiring

    2. Installation and wiring 2.1 Attention: There are many plastic parts in this instrument panel. Please do use dry soft cloth for cleaning. Solvents are not allowed for cleaning. Please keep the LCD screen away from any sharpen goods. Please keep any mechanical impact away during the instrument working. It might cause internal component damage or system breaks down.
  • Page 10 Tightening screw Clamp strip Thickness≥4mm Face out Thickness≥4mm Clamp strip Figure 2-2-3 Terminal arrangements are descripted on Figure 2-2-4-A and Figure 2-2-4-B. Signal input / Control output: Input/Output Description terminal symbol L、N、G Power terminal and Grounding Analog A、B、C input terminal,Max 8 channels (ASR300 ) DC24V Power output terminals, Max3,60mA each,for converter power P+、P- supply...
  • Page 11 Maximum 12 channels input will be available, Take No.1 input signal for example as below,similar to others Terminal 1 A B C A B C A B C A B C A B C A B C A B C A B C Figure 2-2-4-2 Termina2...
  • Page 12 1. (Line), N (Nuture), G (Ground) 2. Before wiring inputs ensure power supply is correct. 3. Input wiring must be under power off condition. G N L Termina 2 Power connecting terminal AC90~260V 50/60Hz Analog input signal connection and wiring are shown as Figure 2-2-5-2A and 2-2-5-2B, Converter connection is shown as Figure 2-2-5-2C remove terminal cover For your convenient, wiring should be from low to high...
  • Page 13 RTD input T.C input Frequency input transmitter wiring diagram Figure 2-2-5-2B Frequency input、transmitter wiring diagram 2 wires transmitter 4 wires transmitter 3 wires transmitter Figure 2-2-5-2C Transmitter wiring diagram 1、 RS-232C connection The RS-232C port is at the back of the instrument. ( Figure 2-2-5-3-1A and 2-2-5-3-1B) , It can be used for both data transferring with computer and serial printer as well.
  • Page 14 Yellow Yellow Black Black 9 pins female socket 9 pins female socket Computer side Instrument side Figure 2-2-5-3B RS-232C com between computer and instrument 2、 RS-485 Com connection By using RS-485 communications with the computer, communication converter (RS232 to RS485) is needed. See Figure 2-2-5-3-2A The RS-485 transmission line should use the shielded twisted pair.
  • Page 15 Turn on the power with the grounding. (Default configuration is 220VAC). (First time power on is suggested that do not connect any input). After 4 Seconds initialization, below status will be seen. Figure 3-1 There are 14 function kays as 3-1 shown. Channel selection Left/Right shift.
  • Page 16 “F1” is a special function key. It will combine with others keys and perform some special functions. It will descript later; “F2” is another special function key. It will combine with others keys and perform some special functions. It will descript later; “Page Down”...
  • Page 17 Press“ ”+“ ”, will see “PUR password”as Figure 3-2-3. Press “ ”shift forward and press“ ”shift back ward. Press“ ”to change user’s name and “ ” or “ ”to change the password. Figure 3-2-3 Under trend, single CH and History recall display, press“ ”will change display curve time division rate.
  • Page 18 Under system display, press“ENT”goto display menu. There are total 3 levels menu as shows in Figure 3-2-6. “ > ”mark is showing that there are more option in the menu of the following levels. level menu level menu level menu Figure 3-2-6 Note: For some new revsion recorder, once the U drive inset into the recorder, it will active “U drive option”...
  • Page 19 Press “ ” ck the current display. Otherwise it will return back to Main automatically after 4 minutes duration without operating. The displaying status is in the top of screen, it is the information of the current operation status. Seem that something is wrong in next page. Please discuss on it. 08-03-07 11:11:25 Trend ○...
  • Page 20 SWP-ASR300 is a TFT with system configuration and help function(included: multi-channels main display, alarm display, single/dual/whole channels displays, bar graphic, history recall and even log as well. 4.1 Trend Trend display is shows as Figure 4-1A It is included bar graph and channel real time data as well. Time div Curve Bar Graphic...
  • Page 21 Vertical diplay, real time readings are in different display mode Vertical trend without channel number Vertical trend with channel number Horizontal trend without channel number Horizontal trend with channel number No grid display mode Solid line grid display mode Figure 4-1B - 21 -...
  • Page 22 It displays 4 alarm modes for all channels. H: Upper limit alarm L: Lower limit alarm J3: Action relay number. Figure 4-3 is a single channel display mode. It will include real time data, display curve, bar graphic and alarm status as well. Measuring data will change to red color once alarm to be activated. CH No.
  • Page 23: Alarm Log

    CH No. Unit Real time data Alarm mark Figure 4-5 4.6 Alarm log The latest 12 alarm messages per channel are saved in alarm log. The messages are included alarm happening/relieving time, alarm channel number, alarm points and alarm mode as well. Alarm mark turn to red, it means alarm is happening, green means alarm is relieving.
  • Page 24 Figure 4-7B Figure 4-7A It displays the instrument power failure (off) record information. It included: total number of power failure (off), duration per power failure (off) and total power failure (off) accumulating time. There are maximum 11 messages per display. Refer to Figure 4-8. Current page record...
  • Page 25 T4 recall modes: close recall, stepping recall, continue recall, timer recall Move cursor on channel display mark CH disables or enable in CH operating mode After ESC, it is for display page up and down; Drawing back from any setting; - Change CH group page;...
  • Page 26 The history recall trend is used for history data inspecting. It is similar with main display as Figure 4-10. There is a time period display under the real time for history recall trend. The value in the recall time period is displaied the measured value upper/lower limit. In the recall trend, the dashed lines expressed the recall locator axis, indicating the position of current recalls which the plot point locates.
  • Page 27 “ ” In vertical display, curve will shift to up if the axis is dashed line, or, the localization axis shifts to up if the axis is solid line. “ ” In vertical display, curve will shift to down if the axis is dashed line, or, the localization axis shifts to down if the axis is solid line.
  • Page 28 It will include instrument hardware and software information: Instrument mode number Software version Serial number Flash space and recording duration capability Circuit diagram Figure 4-11A Figure 4-11B 1) Enter the configuration setting display “ ”+“ ”will display PUR setting page as below. Figure 5-1-1 2) Selection Press“...
  • Page 29 3) Edit the configuration Press “ “ to select the object and press “ “ for editing. Figure 5-1-3 As shows in below: the edit objects are: date, time, password, channel numbers, interval record time, time DIV, TC open circuit display, key sound ON/OFF and screen saving as well. Figure 5-2-1 - 29 -...
  • Page 30 Name Setting range Description Factory Date yy - mm - dd Default Real time Time h : m : s default Real time 00000000—9999999 000000000 Password Preset No. of channels 1 – 12 Preset recording channels Real Interval time 1 – 600 S Interrecord time 1:Rate change as 1,2,4,8 2:Rate change as 1,2,8,16...
  • Page 31 Note:In alarm setting, NULL is no alarm available. “H” is alarm upper limit; ”L” is alarm lower limit; ”R” is rate-of-change upper limit;”r” is rate-of-change lower limit. “h” is differential upper limit and “l” is differential lower limit. Figure 5-2-2C For the differential alarm, presents a single direction arrow in the bargraph.
  • Page 32 Figure 5-2-2E If input signal is lower or higher than range setting, system will remind it. Engineering unit table Unit type Engineering unit Temperature ℃、℉ Pressure bar、mbar、mmHg、mHg、mmH O、mH O、kgf/cm²、atm、Pa、KPa、MPa t/s、t/min、t/h、L/s、L/min、L/h、Kg/s、Kg/min、Kg/h、m³/s、m³/min、m³/h、 Flow volume /s、Km /min、Km /h、Nm /s、Nm /min、Nm Weighth t、Kg、g Volume mL、L 、KL 、mm cm³、m³、Nm³...
  • Page 33 “√” in below will be able to display in mode list. Figure 5-2-3BS Figure 5-2-3A “ ” 、“ ” Left/right shift and select display mode “ ” 、“ ” Enable /disable display mode The following settings are included com type, instrument DE #, buad rate selecting, IP address. NAME SETTING RANGE CONTENTS...
  • Page 34 μ P-A40 micro Pinter is recommended. As Figure 5-2-6 shows: Purview mamagement used instrument password control and number of users. Higher level parameters can only accessed by administrator. Figure 5-2-6A Figure 5-2-6B   User can only change their own’s password. ...
  • Page 35 Figure 5-2-6C Figure 5-2-6D Figure 5-2-6D, click “Operating record display”, It will be show as Figure 5-2-6E Current time Display mode Record # Event detail Event time Figure 5-2-6E Note:System can display different mode of events by press if events number is not enough to display in one line.
  • Page 36 Figure 5-2-6D Figure 5-2-6F Figure 5-2-6E: the advance administrator can create 3 sets of configuration backup file with referring time. User can restore instrument setting accordingly. The backup parameters can also be reset by pressing CANCEL   It is only “1# administrator” The highest purviewer)can access and change. It include: number of operaters, number of administrators, purview level and recorver initial user password.
  • Page 37 Name Setting range Description Factory setting Analog Analog 1 - 4 Real value output output CH tags Output modes Voltage, Current Setting the signal mode of linear output Real value Setting the CH’s of linear output. NULL is NULL、1 - 9 Sampling CH NULL no output.
  • Page 38 Figure 5-2-8 SWP-ASR300 A series will be able to communicate with computer by using RS-232C or RS-485. Either of them is selectable. The SWP-ASR300 A series chart recorder management software is ready for user to remoting moniter, configuration setting, data transferring, and profile printing as well 6.1 Communicating connection 接地线...
  • Page 39: Specification

    – – Spec. Additional Model description code code ASR301 ASR300 (1 ch) ASR302 ASR300 (2 ch) (standard configuration) ASR303 ASR300 (3 ch) ASR304 ASR300 (4 ch) ASR305 ASR300 (5 ch) ASR306 ASR300 (6 ch) ASR307 ASR300 (7 ch) ASR308 ASR300 (8 ch) ASR309 ASR300 (9 ch) ASR310...
  • Page 40 *3. If analog output or frequency input are selected, the maximum universal inputs number will be 8 (Please refer to manual detail) e.g.: ASR108-2-1/J4/C2 Instrument dimension is 144×144×240, 8 channels, English revision ASR chart recorder. With 4 relay outputs (normally open) and RS-232 comm port, 64MB internal memory capacity.
  • Page 41 Please ensure instrument calibration yearly. There are some calibration tools recommended: Standard DC voltage signal generator (Output: 20mV—20V Accuracy ±0.005%); Variable resistor (Output: 0.1—500Ω Accuracy ±0.001% Resolution 0.001 Ω). Calibration process: 1 Power up instrument with correct GND, warmup 30 minutes or above; 2 Ensure environments is instrument acceptable condition;...
  • Page 42 Singapore Distributor: Wall Technology Pte Ltd CHARM FAITH AUTOSYSTEM CO.,LTD. www.walltechnology.net 17th Floor,Fairmont House,8 Cotton Tree Drive,Central,Hong Kong 21 Toh Guan Road East Toh Guan Centre 07-07 S’ 608609 Tel:00852-31190198 Fax:00852-25305488 Tel: 65-63165501 Web: http://www.swp.com.cn Email: swp@swp.com.cn - 42 -...