Safety
International Safety Symbols
This symbol, adjacent to another symbol or terminal, indicates the user must refer
to the manual for further information.
This symbol, adjacent to a terminal, indicates that, under normal use, hazardous
voltages may be present
Double insulation
SAFETY NOTES
Do not exceed the maximum allowable input range of any function
Do not apply voltage to meter when resistance function is selected.
Set the function switch OFF when the meter is not in use.
WARNINGS
Set function switch to the appropriate position before measuring.
When measuring volts do not switch to current/resistance modes.
Do not measure current on a circuit whose voltage exceeds 240V.
When changing ranges using the selector switch always disconnect the test leads from
the circuit under test.
Do not exceed the maximum rated input limits.
CAUTION !!
Improper use of this meter can cause damage, shock, injury or death. Read and
understand this user manual before operating the meter.
Always remove the test leads before replacing the battery.
Inspect the condition of the test leads and the meter itself for any damage before
operating the meter. Repair or replace any damage before use.
Use great care when making measurements if the voltages are greater than
25VAC rms or 35VDC. These voltages are considered a shock hazard.
Remove the battery if the meter is to be stored for long periods.
Always discharge capacitors and remove power from the device under test before
performing Diode, Resistance or Continuity tests.
Voltage checks on electrical outlets can be difficult and misleading because of the
uncertainty of connection to the recessed electrical contacts. Other means should
be used to ensure that the terminals are not "live".
If the equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired.
DC CLAMP METER (1000A)
MODEL BK 700-2606
USER INSTRUCTIONS
Function
A AC
V DC, V AC
Resistance, Diode, Continuity, Capacitance,
Frequency, Duty Cycle, Test
Temperature (℃/℉)
METER DESCRIPTION
1. Current clamp
2. Clamp trigger
3. Data Hold and Backlight button
4. Mode select button
5. Hz/% button
6. LCD display
7. COM input jack
8. Rotary Function switch
9. ZERO button
10. Range select button
11. V Ω℃/℉ jack
** Battery compartment on rear
DISPLAY
1.
AC / DC
2.
(to left of reading)
3.
8.8.8.8
4.
AUTO
5.
•)))
6.
7.
HOLD
℃,℉, ,m,V,A,K,M,Ω,
8.
INPUT LIMITS
Maximum Input
1000A
600V DC/AC
250V DC/AC
60V DC/24V AC
1
A
400A
40A
2
8
3
9
4
Hz%
5
6
¡ ã
C
DC
¡ ã
F
A
AC
m V
k M
7
AC (Alternating Current) and DC (Direct Currrent)
Minus sign (if applicable)
4000 count (0 to 3999) measurement reading
AutoRange mode
Diode test mode
Audible Continuity
Data Hold mode
Units of measure list
n
u

Advertisement

loading

Summary of Contents for Napa BK 700-2606

  • Page 1 DC CLAMP METER (1000A) MODEL BK 700-2606 INPUT LIMITS Function Maximum Input USER INSTRUCTIONS A AC 1000A V DC, V AC 600V DC/AC Safety Resistance, Diode, Continuity, Capacitance, 250V DC/AC Frequency, Duty Cycle, Test International Safety Symbols Temperature (℃/℉) 60V DC/24V AC This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.
  • Page 2 SPECIFICATIONS SPECIFICATIONS (CONTINUED) FUNCTION RANGE & RESOLUTION ACCURACY (% of reading) Measurements Rate 2 per second, nominal 40.00 AAC ± (2.8% + 10 digits) Input Impedance 7.8M (VDC and VAC) DC Current 400.0 AAC ± (2.8 % + 5 digits) Display 4000 counts LCD 1000 AAC...
  • Page 3 REPAIRS: MAIL TESTER FREIGHT PREPAID TO: WARNING:To avoid electric shock, disconnect both test probes from any source of NAPA Meter Repairs / 139 Elizabeth Ln. / Genoa City, WI 53128 voltage before making a temperature measurement. NOTE: RETURNS AUTHORIZATION and BRIEF DESCRIPTION OF PROBLEM MUST ACCOMPANY...