Office Data Copy - NEC NEAX2000 IVS2 Installation Manual

Integrated voice server
Hide thumbs Also See for NEAX2000 IVS2:
Table of Contents

Advertisement

Office Data Copy

There are two ways for office data copy as follows.
• Automatic Office Data Copy
When a Stand by MP starts:
3 to 6 minutes later after the MP card has entered into a stand by mode, all office data is
copied from the active MP card to the stand by MP card automatically.
At a Predetermined Time:
The office data is copied automatically from the active MP card to the stand by MP card at
the predetermined time assigned by CM43 Y=4 once a day.
• Manual Office Data Copy
Set the data for manual office data copy as follows.
CMEC Y=5>0: 0 (start copy)
NOTE:
"1" is displayed during the office data is being copied.
2
NEAX2000 IVS
Installation Procedure Manual
ND-70928 (E), Issue 3.0
CHAPTER 2 INSTALLATION
BACKUP CPU SYSTEM
Page 229