Counterweight Removal/Install Device Alarm
When oil pressure in the counterweight removal/install
device cylinder increases, an alarm sounds continuously and
background of icon (2) turns red on the monitor.
Icon indicates warning situation.
(Red background)
IMPORTANT:
Do not operate the machine if the buzzer sounds
when the counterweight is fully installed. Failure to
follow direction may cause serious damage to the
counterweight removal/install device. If the buzzer
sounds, immediately check and ensure the stop
valve is fully closed and the lifting yoke is in the REST
position by operating the counterweight removal/
install operation lever. Refer to counterweight
removal/install sections for information on
counterweight operation.
If the buzzer sounds while the counterweight is
removed and the remove and install arm is in the
up position, fully close the stop valve and lower
the counterweight removal/install device until the
clearance (C) between the device and the machine
frame becomes approximately 100 mm by operating
the counterweight removal/install operation lever.
After that, be sure to fully open the stop valve.
OPERATOR'S STATION
2
Lifting Yoke REST Position
C
Inside Pump Compartment Door
2
MJAA-NACW1-003
Lifting Yoke
MJAA-NACW1-017
MJAA-NACW1-009
Counterweight
Removal/Install
Operation Lever
Stop Valve
MJAA-NACW1-013