IC401 VHiLC78646E-1: Servo/Signal Control (LC78646E) (2/2)
Pin No.
Terminal Name
Input/Output
44
RVSS
45
RCHO
46
RVDD
47
XVDD
48
XOUT
49
XIN
50
FSX/16MIN
51
XVSS
52*
C2F
53*
EFLG
54
16MOUT
55
ASLRCK
56
ASDACK
57
ASDFIN
58
LRCK
59
DATACK
60
DATA
61
CE
62
CL
63
DI
64
DO
65
*WRQ
66
*RES
67
DRF
68
VDD5
69
VSS
70
CONT3
71*
CONT2
72*
CONT1
73*
PDO1
74
PDO2
75
VVSS
76
PCKIST
77
VVDD
78
FR
79
LDS
80
LDD
In this unit, the terminal with asterisk mark (*) is (open) terminal which is not connected to the outside.
Be sure to supply the same potential to each power terminal. (VVDD, ADAVDD, VDD, LVDD, RVDD, XVDD)
Terminal witch is controlled by the power terminal (VDD5 V) for a microcomputer interface:
CE (61 pin), CL (62 pin), DI (63 pin), DO (64 pin), WRQ (65 pin), RES (66 pin), DRF (67 pin)
Setting in Reset
Output
LVDD/2
Input
Input
Output
Oscillator
Input
Oscillator
Input/Output
Input
Output
H
Output
L
Output
Clock
Input
Input
Input
Output
L
Output
L
Output
L
Input
Input
Input
Output
(H)
Output
H
Input
Output
L
Input
Input/Output
Input
Input/Output
Input
Input/Output
Input
Output
Output
Input
Input
Input
Input
Input
Output
GND for Right channel. Must be connected to 0 V.
Right channel
Right channel output.
D/A converter
Power supply for Right channel.
Power supply for crystal oscillator.
Crystal
Connected for the 33.8688 MHz crystal oscillator cie-
Oscillator
ment.
7.35 kHz Synchronization signal monitor port.
or Clock input port for Digital filter & D/A
Crystal
GND for crystal oscillator. Must be connected to 0 V.
Oscillator
C2 FLAG monitor port.
C1, C2 error corrected monitor port.
16.9344 MHz output port.
Left/Right clock input port.
(If this port does not use, must be connect to 0 V.)
Bit clock input port.
Anti-shock
(If this port does not use, must be connect to 0 V.)
Left/Right channel data input port.
(If this port does not use, must be connect to 0 V.)
Left/Right clock output port.
Digital data.
Bit clock output port.
Left/Right channel data output port.
Chip enable signal input port.
Data transfer clock input port.
Microcomputer
Data input port.
Interface
Data output port. (N-ch. open drain output.)
Interruption signal output.
Chip reset signal input port.
This port must be set LOW after first applied power on.
Focus detection output port.
Power supply for Microprocessor.
GND for digital circuit. Must be connected to 0 V.
General purpose port 3.
General purpose port 2.
General purpose port 1.
Internal VCO control phase comparator output port 1.
Internal VCO control phase comparator output port 2.
GND for internal VCO. Must be connected to 0 V.
PLL
PDO output current adjustment resistor connection port.
Power supply for internal VCO.
VCO frequency range adjustment port.
LASER power detected signal input port.
LASER power control signal output port.
8 – 2
XL-ES5/ES50
Function
Controlled with serial data command from
microcomputer. When not used, General
purpose input/output terminal. Set it as the
input terminal and open it by connecting to
0 V, or set it as the output terminal and
open it.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xl-es50

Table of Contents