NDUSTRIA NEL-15B Installation, Operation & Service Manual

Infrared wall mounted electric heater

Advertisement

Quick Links

WARNING
Fire Hazard
Keep all flammable objects, liquids and
vapors the minimum required clear-
ances to combustibles away from
heater.
Some objects will catch fire or explode
when placed close to heater.
Failure to follow these instructions can
result in death, injury or property
damage.
NOT FOR USE IN HAZARDOUS
OR EXPLOSIVE ATMOSPHERES
WARNING
Improper installation, adjustment, alteration, service
or maintenance can result in death, injury or
property damage. Read the Installation, Operation
and Service Manual thoroughly before installing or
servicing this equipment.
Installation must be done by a contractor qualified
in the installation and service of electric heating
equipment.
FOR INDOOR/OUTDOOR COMMERCIAL/INDUSTRIAL USE
& OUTDOOR RESIDENTIAL USE
IP65 Rated Water Resistant
Please take the time to read and understand
these instructions prior to any installation.
Installer must give a copy of this manual to the owner.
Keep this manual in a safe place in order to provide
your service technician with necessary information.
© 2021 Ndustria
Installer
Owner
Infrared Wall Mounted
Electric Heater
Installation, Operation &
Model
NEL-15B
NEL-15G
NEL-15B-RM
NEL-15G-RM
NEL-30B
NEL-30G
NEL-60B
NEL-60G
NDUSTRIA™
100 Seven Mile Rd NW
Comstock Park, MI 49321
Telephone: +1.716.551.7900
www.ndustria.com
Service Manual
Volts
Watts
120
1500
120
1500
120
1500
120
1500
208/240
2250/3000
208/240
2250/3000
208/240
4500/6000
208/240
4500/6000
P/N NDEL400NA Orig 3/21

Advertisement

Table of Contents
loading

Summary of Contents for NDUSTRIA NEL-15B

  • Page 1 Installer must give a copy of this manual to the owner. Owner Keep this manual in a safe place in order to provide NDUSTRIA™ your service technician with necessary information. 100 Seven Mile Rd NW Comstock Park, MI 49321 Telephone: +1.716.551.7900 www.ndustria.com © 2021 Ndustria P/N NDEL400NA Orig 3/21...
  • Page 3: Table Of Contents

    All rights reserved. No part of this work covered by the copyrights herein may be reproduced or copied in any form or by any means - graphic, electronic, or mechanical, including photocopying, recording, taping or information storage and retrieval systems - without the written permission of Ndustria.
  • Page 5: Section 1: Heater Safety

    Failure to follow these instructions can result in death, electric shock, injury or property damage. NDUSTRIA infrared heater produces radiant heat that This heater must be applied and operated under the warms people and objects rather than air surrounding general concepts of reasonable use and installed them.
  • Page 6: Section 2: Installer Responsibility

    • To install the heater, as well as the electrical sup- plies, in accordance with applicable specifi cations and codes. NDUSTRIA recommends the installer contact a local Building Inspector or Fire Marshal for guidance. • To use the information given in a layout drawing and in the manual together with the cited codes and regu- lations to perform the installation.
  • Page 7: Section 3: General Installation & Operation

    NDUSTRIA™ Infrared Electric Manual SECTION 3: GENERAL INSTALLATION & OPERATION WARNING DANGER Electrical Shock Hazard Fire Hazard Burn Hazard Keep all flammable Allow heater to cool Disconnect electric before objects, liquids and before service. service. vapors the minimum required clearances to...
  • Page 8: Heater Installation

    NDUSTRIA™ Infrared Electric Manual 3.1 Heater Installation 3.1.1 Clearances to Combustibles 1. Remove heater from packaging, and remove all Minimum clearances to combustibles and tilt an- packing materials including anti-vibration foam around gles must be strictly followed. emitter/lamp. Check heater, power cord, and plug •...
  • Page 9: Mounting

    NDUSTRIA™ Infrared Electric Manual 3.2 Mounting 2. Mount the heater to the brackets with the terminal When attaching brackets for mounting, make sure that box at the bottom of the heater. it is secure to support weight of heater. Keep in mind that mechanical bearing pressure and oscillation due 3.
  • Page 10: Adusting Directional Positioning

    NDUSTRIA™ Infrared Electric Manual 3.2.3 Adusting Directional Positioning 3.3 Operation of Models NEL-15(B/G) and NEL- 15(B/G)-RM DANGER WARNING Electrical Shock Hazard Fire Hazard Disconnect electrical supplies before performing service or maintenance. Turn off heater when not in use. Installation must be done by a certified...
  • Page 11: Remote Control - Model Nel-15(B/G)-Rm Only

    NDUSTRIA™ Infrared Electric Manual 3.3.1 Remote Control - Model NEL-15(B/G)-RM 3.3.2 Remote Control Functionality (optional) Only Requires 2 AAA 1.5V batteries (not included) DANGER Electrical Shock Hazard Disconnect electrical supplies before performing service or maintenance. Installation must be done by a certified electrician and must adhere to local, state and national electrical codes.
  • Page 12: Section 4: Maintenance & Service

    NDUSTRIA™ Infrared Electric Manual SECTION 4: MAINTENANCE & SERVICE WARNING DANGER Electrical Shock Hazard Fire Hazard Burn Hazard Cut/Pinch Hazard Disconnect electric Keep all flammable Keep all persons, Wear protective gear before service. objects, liquids and especially children, during installation, vapors the minimum away from heater.
  • Page 13: Replacing Emmiter/Lamp

    NDUSTRIA™ Infrared Electric Manual 4.2 Replacing Emmiter/Lamp 4.3 Service Contact your distributor for the correct replacement 1. Repairs must be carried out by service specialists to emitter, providing the model number and rating from ensure electrical safety. Contact an authorized ser- the rating label.
  • Page 14: Section 5: General Specifications

    NDUSTRIA™ Infrared Electric Manual SECTION 5: GENERAL SPECIFICATIONS WARNING DANGER Electrical Shock Hazard Fire Hazard Burn Hazard Cut/Pinch Hazard Disconnect electric Keep all flammable Keep all persons, Wear protective gear before service. objects, liquids and especially children, during installation, vapors the minimum away from heater.
  • Page 15: Dimensions

    NDUSTRIA™ Infrared Electric Manual 5.3 Dimensions Weight Length Width Height Model (lbs/kg) (in/cm) (in/cm) (in/cm) NEL-15B 6.6/3 25/63.5 4/10.2 5/12.7 NEL-15G 6.6/3 25/63.5 4/10.2 5/12.7 NEL-15B-RM 6.6/3 25/63.5 4/10.2 5/12.7 NEL-15G-RM 6.6/3 25/63.5 4/10.2 5/12.7 NEL-30B 8.8/4 35/88.9 4/10.2 5/12.7 NEL-30G 8.8/4...
  • Page 16: Section 7: Warranty

    There are no other warranties, express or or component of the system that is not supplied by implied, which extend beyond the description in NDUSTRIA, regardless of the cause of failure of such this document. portion or component. 2. All warranties implied by law are limited in duration to the one-year term of the Parts Warranty.
  • Page 17 NDUSTRIA™ Infrared Electric Manual or fi nal seller may provide a warranty on units sold outside these areas. 5. NDUSTRIA will not be liable for damages if our performance regarding warranty resolution is delayed by events beyond our control including accident, al- teration, abuse, war, government restrictions, strikes, fi re, fl ood, or other acts of God.

Table of Contents