PRESTIGE XL2 Maintenance
DAILY (AM - Mornings):
Shake the leftover White Ink for 30 seconds - 1 minute
▪
Turn the printer on and turn the Hosonsoft on
▪
Increase the WIMS Ink Circulation motor to 60-70, and let the system
▪
circulate/agitate the white ink for 5 minutes. After 5 min., turn off the circulation
motor or set it to 10-20%
Execute "Fill Ink" - we recommend at least 10 seconds for the white ink, and 5
▪
seconds for the CMYK ink. Check if you can see both inks flowing down to the
waste bottle without air bubbles.
Menu -> Head Maintain -> Fill Ink
▫
Execute "Cleaning" - press the cleaning button on the control panel
▪
Pull the media to the front by pressing the down button on the control panel to
▪
get it ready for a nozzle check pattern
Perform a "Nozzle Check" - check the patterns and see if there are any breaks
▪
If there are severe breaks in the pattern, execute fill ink and clean one
▫
more time to improve the pattern
One you achieve a perfect nozzle check, you can proceed to print
▫
▪
DAILY (PM - Evenings):
Retract the media to the media roller by pressing the up button on the control
▪
panel
Clean the vacuum bottom platen with a microfibre cloth or lint-free cloth. Do
▪
not use cleaning solution. You may use 90% or higher isopropyl alcohol.
Move the printhead carriage to the left side by pressing the left button once to
▪
disengage the carriage from the capping station. Then, press and hold the left
button to slide the head carriage.
Clean/Wipe the capping station, rubber gaskets, and wiper blades with
▪
cleaning solution using a cleaning swab
Clean around the head with cleaning solution to remove any excess ink
▪
build-up. DO NOT touch the actual head using a cleaning swab
Wet Cap: pour cleaning solution into the capping station rubber gaskets
▪
Engage the printhead back to the capping station by pressing the "Enter"
▪
button on the printer control panel
Turn off the printer for the night
▪
Cover the printer with a printer cover to prevent any dust
▪
You may also start printing if there are only 2-3 missing dots per
nozzle