Pre-installation — device location preparation
The MTP T 15HD A WM and D models can be installed in 1-gang electrical wall boxes, and the
MTP T 15HD A AAP can be attached to a device faceplate or an AAP wall plate. Refer to the
MTP T 15HD A Architectural Twisted Pair Transmitters User's Guide, for installing the electrical
box or wall plate.
Run the twisted pair and audio output cables from
the output device locations to the MTP T 15HD
location in preparation for the final installation.
Terminate TP output cables as shown on the
N
right, using the same standard (A or B) at
both ends.
Run the 12 VDC power supply to the MTP T 15HD
location.
Installation
Step 1 — Cabling and mounting
Turn off or disconnect all equipment power sources.
a. Power — Plug the 12 VDC power supply into the rear panel,
direct insertion, 3.5 mm, 2-pole captive screw connector.
Wire the connector as shown.
b. Pre-peaking — Set the pre-peaking switch on the rear panel for
long cable runs as desired. Refer to the switch settings table in
the online MTP T 15HD A Architectural Twisted Pair Transmitters User's Guide.
c. Output cabling — Connect the TP cable to the rear panel RJ-45 connector.
d. Audio cabling — For local stereo output, insert stripped audio cable into the
3.5 mm, 5-pole direct insertion captive connector, as shown below.
Do not tin the wires!
Tip
See Caution
Sleeve (s)
Tip
See Caution
Unbalanced Stereo Output
CAUTION
For unbalanced audio, connect the sleeve(s) to the center contact
ground.
This card provides basic instructions for an
experienced installer to set up and operate
the Extron MTP T 15HD A Architectural
Series products; the MTP T 15HD WM,
MTP T 15HD D, and MTP T 15HD AAP
models.
Refer to the MTP T 15HD A Architectural
Twisted Pair Transmitters User's Guide (available at www.extron.com) for detailed
information.
0.2" (5 mm) max.
Tip
Ring
Sleeve (s)
Tip
Ring
Balanced Stereo Output
DO NOT
connect the sleeve(s) to the negative (-) contacts.
Pins:
12345678
T568A
Pin
Wire color
1
White-green
2
Green
3
White-orange
4
Blue
5
White-blue
6
Orange
7
White-brown
8
Brown
Insert Twisted
Pair Wires
NOTE
If you are using Enhanced
RJ-45
Skew-Free™ A/V cable, use the
Connector
TIA/EIA T568A standard only.
Smooth
A
SECTION A–A
Power Supply
Output Cord
(Continued on reverse side)
T568B
Wire color
White-orange
Orange
White-green
Blue
White-blue
Green
White-brown
Brown
Captive Screw
Connector
Ridges
A
0.2" (5 mm)
MAX
ON
PRE-
PEAK