Connecting The Vent System - Samsung NK30CB600W Series Installation & User Manual

Hide thumbs Also See for NK30CB600W Series:
Table of Contents

Advertisement

Installation

Connecting the Vent System

NK3*CB600W**
NK3*CB700W**
12
5.
Assemble the damper or the electric
damper for preventing backflow by
tufning It in to the hood exhaust
outlet.
NOTE
• Damper is provided in NK3*CB600W**.
• Electric Damper is provided in
NK3*CB700W**.
CAUTION
Check that the electric damper is seated
correctly on the screw thread and there
is no tilt. If the electric damper is not
flush, air will leak through the gap.
6.
Assemble the damper adapter,
pushing it into a damper or electric
damper. Fix it using tape.
NOTE
• If the hood is NK3*CB600W**,
please follow it from No.10.
• If the hood is NK3*CB700W**,
please follow it from No.7.
7.
Remove the cover by loosening the
screw on the PCB cover.
8.
Connect the connector of the electric
damper wire and the PCB connector.
NOTE
Insert the wire into the hole at the top
left corner.
9.
Assemble the PCB cover using a
screw.
NOTE
Put the connected connector into the
hole of the cover as shown in the
picture.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nk36cb600w series

Table of Contents