SPECIFICATIONS
150±10
G½
OPERATING CONDITIONS
1. Water supply pressure : 0.05 ~ 0.75 MPa.
2. Ensure that water supply is clean ( No Sand, Dirt, Etc.).
ATTENTION
1.
Don t use abrasive cleaners or solvents on faucets and
fittings.
2.
Flow Regulator should not be remove because it could
damage the system
3.
As the product model is constantly updated, the actual
product may not look the same as it shown in the diagram,
but the basic installation principles are the same.
4.
The hot water supply side of the faucets is in a condition of
high temperature. Do not allow skin to contact with the
hardware surface directly. Otherwise, scalding may occur.
S060261N
INSTALLATION
1
MOUNT CONNECTORS PARALLEL WITH THE WALL
Hot
Water
Supply
WALL
Leg
2
74
30
Body
* Tighten the nut by wrench
3
0
62
-7
Hand Shower
"UMI" SINGLE LEVER SHOWER SET TX474SUN
Cold
150±10
Water
Supply
Use Seal Tape
(Not Include)
150
Packing
Cover
Nut *
Packing
Sleeve
Flexible Hose
Anchor
Hanger
Screw
2 X Ø5.5
Holes
Packing
TROUBLESHOOTING
CHECK
PROBLEM
POINT
1
Unsatisfactory spray
Water leaks around the handle
2
Handle is loose
3
1. NOZZLES
Flow Regulator Inside
(Don t remove)
3. BOLT
2. CONNECTING NUT
MAINTENANCE
All Finishes : Clean the finish with mild soap and warm
water. Wipe entire surface completely dry with clean soft
cloth. Many cleaners may contain chemicals, such as
ammonia, chlorine, toilet cleaner etc. which could adversely
affect the finish and are not recommended for cleaning
SOLUTION
Clean
Tighten
Tighten
R7