12 The exchange method of pan sensor and thermal fuse
1
Remove the cast heater
• To remove the cast heater, please refer to "The exchange method of cast heater" (Item 1 to 3, P16).
2
Remove pan sensor
• Loosen and stretch out the claws (3 places) and take out
the pan sensor.
NOTES:
NOTES:
• Care must be taken to avoid the spring for sensor from
deformation when removing.
3
Exchange thermal fuse
• The replacement of pan sensor is the exchange of thermal fuse A/B.
This is because the thermal fuse A/B are both fi xed within the pan sensor.
4
Reassembly
• Reassemble the new pan sensor in reverse order for disassembly.
NOTES:
NOTES:
• Care must be taken to avoid the spring for sensor from deformation when reassembling.
• Care must be taken to avoid the spring for sensor from tilting when reassembling.
• Refer to P5 for wiring connection.
• Please note the direction of pan sensor.
claws (3 places)
Thermal Fuse B
Thermistor
25
Thermal Fuse A