Power Supply CBA Top View
CAUTION
FOR CONTINUED PROTECTION AGAINST FIRE HAZARD,
F
REPLACE ONLY WITH THE SAME TYPE FUSE.
ATTENTION : POUR UNE PROTECTION CONTINUE LES RISQES
D'INCELE N'UTILISER QUE DES FUSIBLE DE MÊME TYPE.
A
V
RISK OF FIRE-REPLACE FUSE AS MARKED.
"This symbol means fast operating fuse."
"Ce symbole reprèsente un fusible à fusion rapide."
L003
Junction CBA Top View
CAUTION !
Fixed voltage ( or Auto voltage selectable ) power supply circuit is used in this unit.
If Main Fuse (F1001) is blown, check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
NOTE :
The voltage for parts in hot circuit is measured
using hot GND as a common terminal.
Junction CBA Bottom View
1-11-27
Power Supply CBA Bottom View
NOTE :
Either BH9400F01021, BH9400F01022
is used for the Junction CBA in this S/M.
BH9400F01021B
BECAUSE A HOT CHASSIS GROUND IS PRESENT IN THE POWER
SUPPLY CIRCUIT , AN ISOLATION TRANSFORMER MUST BE USED.
ALSO , IN ORDER TO HAVE THE ABILITY TO INCREASE THE INPUT
SLOWLY , WHEN TROUBLESHOOTING THIS TYPE POWER SUPPLY
CIRCUIT , A VARIABLE ISOLATION TRANSFORMER IS REQUIRED.
NOTE :
Either BH9400F01021, BH9400F01022
is used for the Power Supply CBA in this S/M.
Power Supply CBA
Parts Location Guide
Ref No.
ICS
IC1001
IC1006
TRANSISTORS
Q1001
Q1003
Q1008
CONNECTORS
CL1002
CL1006
1-11-28
BH9400F01021A
Position
B-1
B-1
B-1
A-2
A-2
C-2
C-1