Outdoor Unit
• IN THE EVENT THAT THE REFRIGERANT GAS LEAKS OUT OF THE PIPE DURING
THE INSTALLATION WORK, IMMEDIATELY LET FRESH AIR INTO THE ROOM.
IF THE REFRIGERANT GAS IS HEATED BY FIRE OR SOMETHING ELSE, IT CAUSES
GENERATION OF POISONOUS GAS.
• WHEN INSTALLING OR RE-INSTALLING THE AIR CONDITIONER, DO NOT INJECT
AIR OR OTHER SUBSTANCES BESIDES THE DESIGNATED REFRIGERANT "R32"
INTO THE REFRIGERATING CYCLE.
IF AIR OR OTHER SUBSTANCES ARE MIXED, AN ABNORMAL PRESSURE CAN
OCCUR IN THE REFRIGERATING CYCLE, AND THIS CAN CAUSE AN INJURY DUE
TO A PIPE RUPTURE.
About the refrigerant
• This product contains uorinated greenhouse gases.
• Do not vent gases to the atmosphere.
• The appliance shall be stored in a room without continuously operating ignition sources
(for example: open ames, an operating gas appliance or an operating electric heater).
• Do not pierce or burn refrigerant cycle parts.
• Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacturer.
• Be aware that refrigerants may not contain an odour.
• The refrigerant inside the unit is ammable. If the refrigerant leaks in the room and comes
in contact with re from a burner, a heater, or a cooker, it may result in re or the formation
of a harmful gas.
• Turn off any combustible heating devices, ventilate the room, and contact the dealer from
which you purchased the unit.
• Do not use the unit until a service person con rms that the portion from which the
refrigerant leaked is repaired.
• When installing, relocating, or servicing the air conditioner, use only the speci ed
refrigerant (R32) to charge the refrigerant lines. Do not mix it with any other refrigerant
and do not allow air to remain in the lines.
• Pipe-work shall be protected from physical damage.
• Compliance with national gas regulations shall be observed.
• Do not use any refrigerant different from the one speci ed for complement or replacement.
Otherwise, abnormally high pressure may be generated in the refrigeration cycle, which
may result in a failure or explosion of the product or an injury to your body.
• Installation work must be requested from the supplying retail dealership or professional
vendors. Self-installation may cause water leakage, electrical shock, or re as a result of
improper installation.
DANGER