Environmental Standards; Power Cord Requirements For Ac-Powered Switches And Ac Power Supplies - Extreme Networks 8820 Hardware Installation Manual

Table of Contents

Advertisement

Extreme 8820 Series Technical Specifications
Table 18: IEEE Media Access Standards (continued)
802.3ah Ethernet in the First Mile Link OAM3
ITU-T G.8013/Y.1731 OAM mechanisms for Ethernet
G.8032

Environmental Standards

Operating conditions
Storage & transportation conditions
(packaged)

Power Cord Requirements for AC-Powered Switches and AC Power Supplies

An AC power cord is not included with the AC power supply.
Power cords used with AC-powered switches or AC power supplies must meet the following
requirements:
The power cord must be agency-certified for the country of use.
The power cord must have an IEC320-C13 connector for connection to the switch or power supply.
The power cord must have an appropriately rated and approved wall plug applicable to the country
of installation.
For cords up to 6 feet (2 m) long, the wire size must be 18 AWG (.75 mm
minimum wire size is 16 AWG (1.0 mm
The power cords for switches that use either the 1100 W or 715 W power supplies are keyed with a
"notch" to ensure the proper orientation when plugged in. These cords are of 3x14 AWG.
For details about obtaining AC power cords for use in your country, refer to
www.extremenetworks.com/product/powercords/.
Operating temperature and operating altitude for
airflow front to back: 0°C to 40°C (32°F to 104°F) /
6.000 ft (1,800m)
Operating temperature and operating altitude for
airflow back to front: 0°C to 25°C (32°F to 77°F) /
6.000 ft (1,800m)
Humidity: 5% to 95%, at 40°C (104°F), non-
condensing
Operational shock (half sine): 30G, Duration=11 ms.
(Half sine), 3 axis.
Operational random vibration: 3-500Hz, 1.5Grms,
120mins, z-axis.
Storage temperature: -40°C to 70°C (-40°F to158°F)
Storage and transportation humidity: 95% maximum
relative humidity, non-condensing
Storage altitude: 15,000 ft (4,500 m) maximum
Packaged shock (half sine): 3 axes, 100 shocks each
axis (+/-) <50 kg: Half-Sine, 180 m/s2 (18g), 6ms
>50kg: Half-Sine, 100 m/s2 (10g), 11ms
Packaged random vibration: 5-20 Hz @ .01 g2/Hz
(PSD). 20-200 Hz @ -3 (dB/Oct (PSD). 30 minutes
per each axis.
2
).
Extreme 8820 Hardware Installation Guide
Environmental Standards
2
) minimum; over 6 feet, the