84VP5/84VM5 Installation Guide
(also a reference for optional Quad Mount used with 42VM5 or 42VP5)

Control

Connections
Connections should be made as described below.
plasma monitor
1) Connector on the plasma monitor side: EXTERNAL CONTROL connector.
Type of connector: D-Sub 9-pin male
N
Pin Name
o.
1
No Connection
2
RXD (Receive data)
3
TXD (Transmit data)
4
DTR (DTE side ready)
5
GND
6
DSR (DCE side ready)
7
RTS (Ready to send)
8
CTS (Clear to send)
9
No Connection
2) Connector on the external equipment side: Serial port (RS-232C) connector. See the specifications of the equipment that
is to be connected for the type of connector and the pin assignment.
3) Wiring
Use a crossed (reverse) cable.
Wire the cable so that each pair of data lines cross between the two devices. These data line pairs are RXD (Receive
data) and TXD (Transmit data), DTR (DTE side ready) and DSR (DCE side ready), and RTS (Ready to send) and CTS
(Clear to send).
Communication Parameters
(1) Communication system
(2) Interface
(3) Baud rate
(4) Data length
(5) Parity
(6) Stop bit
(7) Communication code
www.necvisualsystems.com
External equipment
e.g., Personal computer
Asynchronous
RS-232C
9600 bps
8 bits
Odd
1 bit
Hex
NEC Solutions (America), Inc.
(using four 42VM5 or 42VP5 Plasma Displays)
Visual Systems
v1.3