General Information Introduction Section 1 General Information 1.1 Introduction The PrimaPak™ II automatically provides battery power during primary power failure when used with the following radiation monitors: Primalert 10, Primalert 35, and Primalarm (after serial #1827). 1.2 Specifications Input Electrical Rating: 12 VDC, 1.0 Amp, 12 VA Output Electrical Rating: 12 VDC, 500 mA, 6 Watts Capacity: 1200 mAh at 12 V (8.2 end of life) Operating Conditions: 0 –...
Operation Installation Section 2 Operation 2.1 Installation NOTE Manual is written in English. Contact factory for help with the translation of this manual. Disconnect the converter used with the Primalert or Primalarm; it is no longer needed. However, keep it in the event that the Primalert or Primalarm are ever used without the PrimaPak. Select the most favorable location for the PrimaPak, bearing in mind that the interconnecting cable supplied is 36”...
Nuclear Associates 05-441 Operators Manual 2.4 Performance Monitoring Because of the crucial nature of the systems using the PrimaPak (i.e., radiation monitoring), a monthly battery life test should be performed. To do this test, unplug the converter from the power line, thereby placing the Primalert in battery operation.