York LX Series Technical Manual page 9

Split system heat pumps
Hide thumbs Also See for LX Series:
Table of Contents

Advertisement

SYSTEM CAPACITY - Single Piece and Modular Air Handlers
AIR HANDLER
UNIT
MODEL
MODEL
YHE48B22S
AE48CX21
YHE48B22S
AE48DBC21
YHE48B22S
AE48DX21
YHE48B22S
AVC48CX21
YHE48B22S
AVC48DX21
YHE48B22S
AVC60CX21
YHE48B22S
ME14DN21
YHE48B22S
ME14DN21
YHE48B22S
ME14DN21
YHE48B22S
ME16CN21
YHE48B22S
ME16CN21
YHE48B22S
ME16CN21
YHE48B22S
ME16CN21
YHE48B22S
ME20DN21
YHE48B22S
ME20DN21
YHE48B22S
ME20DN21
YHE48B22S
MVC16CN21
YHE48B22S
MVC16CN21
YHE48B22S
MVC16CN21
YHE48B22S
MVC20DN21
YHE48B22S
MVC20DN21
YHE48B22S
MVC20DN21
YHE60B22S
AE60DBG21
YHE60B22S
AE60DX21
YHE60B22S
AVC60DX21
YHE60B22S
ME20DN21
YHE60B22S
MVC20DN21
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ANSI/AHRI Standard 210/240.
1. Cooling MBH based on 80°F entering air temperature, 50% RH (Relative Humidity), and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTUs at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period.
2. Heating MBH based on AHRI standards of 70°F DB (Dry Bulb) entering indoor air, 72% RH (Relative Humidity) outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation.
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period.
COP (Coefficient of Performance) equals Heating MBH output divided by (total KW input x 3.412).
3. CM coils available with a factory installed horizontal drain pan. See price pages for specific model number.
— = Not applicable.
* Notates "Hot Heat Pump" performance. These ratings are not AHRI listed.
MP Modular Air Handlers use Coil Only Ratings.
Johnson Controls Ducted Systems
COIL
RATED
3
MODEL
CFM
WIDTH
21.0
1400
24.5
1400
24.5
1400
21.0
1375
24.5
1400
21.0
1350
24.5
CF/CM48D
1400
24.5
CF/CM60D
1400
24.5
CM48DBCA1
1400
21.0
CF/CM48C
1400
21.0
CF/CM60C
1400
21.0
CF48CBCA1
1400
21.0
CM48CBCA1
1400
24.5
CF/CM48D
1400
24.5
CF/CM60D
1400
24.5
CM48DBCA1
1400
21.0
CF/CM48C
1425
21.0
CF48CBCA1
1425
21.0
CM48CBCA1
1425
24.5
CF/CM48D
1350
24.5
CF/CM60D
1475
24.5
CM48DBCA1
1350
24.5
1650
24.5
1650
24.5
1550
24.5
CF/CM64D
1600
24.5
CF/CM64D
1600
1
COOLING
NET MBH
SEER
EER
TOTAL
SENS.
46.0
31.8
14.25
12.00
46.5
32.0
14.5
12.25
46.5
32.0
14.5
12.25
46.0
31.6
14.25
12.00
46.5
31.6
14.75
12.25
46.5
31.6
15.00
12.50
46.5
32.0
14.50
12.25
46.5
32.0
14.25
12.00
46.5
32.0
14.50
12.25
46.0
31.8
14.50
12.00
47.0
32.2
14.50
12.25
46.0
31.8
14.50
12.00
46.0
31.8
14.50
12.00
46.5
31.8
14.50
12.00
47.0
32.2
14.75
12.25
46.5
31.8
14.50
12.00
46.0
31.8
14.50
12.00
46.0
31.8
14.50
12.00
46.0
31.8
14.50
12.00
46.5
32.0
14.50
12.25
47.5
33.2
15.00
12.50
46.5
32.0
14.50
12.25
55.5
38.6
14.00
12.00
55.5
38.6
14.00
12.00
55.5
39.5
14.25
12.00
55.0
38.0
14.25
12.00
55.5
38.5
14.25
12.00
2
HEATING
NET MBH
HSPF
HSPF
Region IV
Region V
47°F OD 17°F OD
47.5
31.4
9.00
47.5
31.4
9.00
47.5
31.4
9.00
47.5
31.4
9.00
47.5
31.2
9.00
47.5
31.2
9.00
47.5
31.4
9.00
48.0
31.4
9.00
47.5
31.4
9.00
47.5
31.4
9.00
47.5
31.2
9.00
47.5
31.4
9.00
47.5
31.4
9.00
47.5
31.4
9.00
47.5
31.2
9.00
47.5
31.4
9.00
47.5
31.4
9.00
47.5
31.4
9.00
47.5
31.4
9.00
47.5
31.2
9.00
47.5
31.4
9.00
47.5
31.2
9.00
57.0
37.8
9.00
8.65
57.0
37.8
9.00
8.65
57.0
37.8
9.00
57.0
37.6
9.25
57.0
37.6
9.25
5523949-YTG-J-0620
COP
47°F OD 17°F OD
3.58
2.64
3.62
2.66
3.62
2.66
3.56
2.62
3.60
2.66
3.56
2.62
3.60
2.66
3.54
2.60
3.60
2.66
3.58
2.64
3.58
2.62
3.58
2.64
3.58
2.64
3.60
2.66
3.58
2.64
3.60
2.66
3.60
2.64
3.60
2.64
3.60
2.64
3.62
2.68
3.64
2.66
3.62
2.68
3.88
2.82
3.88
2.82
3.88
2.82
3.88
2.82
3.90
2.82
9