Warnings and CALL OUT output

Warnings and their appropriate countermeasures

#1 Options in the CALL OUT options column:
• Selectable : CALL OUT output can be selected/de-selected on the menu.
• Fixed
: a CALL OUT signal is emitted without prior selection of this function using the menu.
• None
: no CALL OUT signal is emitted, but a warning indicator will appear on screen.
CALL OUT signal output can be stopped by pressing the WARNING RESET button.
Warning Display
REC/FULL
COPY/FULL
REST/FULL
REC/REM
COPY/SIZE/DATA ERROR
REST/SIZE/DATA ERROR
COPY/MEDIA ERROR
REST/MEDIA ERROR
COPY/NO MEDIA
REST/NO MEDIA
NON SIGNAL
(The warning will
indicate the number
of the non-functioning
camera. )
IMAGE MODIFIED
SYSTEM ERROR
PLAY/SYSTEM ERROR
REC/SYSTEM ERROR
COPY/SYSTEM ERROR
REST/SYSTEM ERROR
REC/RW
COPY/RW
REST/RW
<DEVICE ERROR>
TEMP
MIRROR
FAN
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
72
Status
• HDD recording capacity is
empty.
• Media recording capacity is
empty.
• The remaining HDD capacity
has reached the value set in
HDD REMAIN.
• The data that is being copied/
restored exceeds the capacity of
the recording device, or there is
no original data.
• Error has occurred in the
Compact Flash Card.
• No Compact Flash Card has
been inserted.
Video signal was lost for more
than 5 seconds during recording.
Video data that has been altered
was played back.
System error has occurred.
Error has occurred during
reading/writing of data to
HDD/media.
Unable to recognize HDD
Issued when in a high
temperature environment within
the tolerance level.
One HDD could not be detected
during mirroring.
The fan stopped.
Countermeasure
• When the warning is cancelled,
the unit will start over-writing
the oldest data remaining in the
hard disk drive.
• Archive or copy data as
necessary.
• Replace with new media.
• Replace media if necessary.
• Copy data as necessary.
• Set the copy/restore range
again.
• Replace the new media.
• Check the Card.
(Insert the media if there
is none.)
• Insert the Card.
• Check whether the unit and
camera are properly connected,
and that electricity is on.
• Check whether the visual signal
is being properly outputted.
• Check to see if there is a
camera set for operation with
no video signal input.
• Reboot.
• Check the HDD/media.
• Check the HDD/media.
• Reboot.
• Turn off the power and change
the installation condition.
• Reboot.
• Turn off the power and stop
usage.
• Request for repair.
CALL OUT
Canceling
Code
the warning
Press the
Selectable
WNG1100
WARNING
RESET button.
Press the
WNG3100
None
WARNING
WNG4100
RESET button.
Press the
WNG1200
Selectable
WARNING
RESET button.
Press the
WNG3701
None
WARNING
WNG4701
RESET button.
Press the
None
WNG3702
WARNING
WNG4702
RESET button.
Press the
WNG3703
None
WARNING
WNG4703
RESET button.
Stop recording.
WNG5400
Fixed
Output video
signals.
Press the
WARNING
RESET button.
Press the
WNG5500
Fixed when
WARNING
setting is
RESET button.
"ON"
Press the
WNG5100
Fixed
WARNING
WNG24
#2
RESET button.
WNG14
#2
WNG34
#2
WNG44
#2
Press the
WNG13
#2
None
WARNING
WNG33
#2
RESET button.
WNG43
#2
Turn off the
Selectable
WNG62
#2
power
Press the
WNG5200
Selectable
WARNING
RESET button.
Lower
the temperature.
Press the
WNG61
#2
Selectable
WARNING
RESET button.
Press the
WNG5300
Selectable
WARNING
RESET button.
Rotate the fan.
#2 :
0 0 : MASTER
0 1 : SLAVE
1 1 : CFC
page
output
#1
43, 46
15
46, 47
62
15, 62
15
16
33
21, 22,
38
43
-
-
48
-
-
-

Advertisement

Table of Contents
loading