• TR342 Round Telescoping Termination Cap
Assemble
Termination
storm collar
Cap
around extended
termination cap
pipe
once cap is
installed.
Caulk gaps between
storm collar & pipe,
Storm
and storm collar
Collar
& chase top.
Collar
2 in. (51 mm)
Minimum Height
Chase Top
Chimney
Pipe
Figure 9.5
Installing a TR342-B Round Telescoping Termination
Cap
• ST375 Square Termination Cap
Flange
Termination Cap
Collar
2 in. (51 mm)
Minimum Height
Chase Top
Chimney
Pipe
Figure 9.6
Installing an ST375 Square Termination Cap
32
Outdoor Lifestyles by Hearth & Home Technologies • 4072-203 Rev E • 11/20
Do NOT
block air
holes
3 clip brackets.
Slip over chase collar
and attach with screws
provided.
The last section of pipe must
stop between 2 in. (51 mm)
above the top of the chase and
4 3/4 in. (121 mm) below the
top of the chase.
2 in. (51 mm)
maximum
4 3/4 in. (121 mm)
Maximum
Chase
Place waterproof
caulk or sealer under
each flange of the
termination cap and
on top of each screw
to help prevent leaks.
The last section of pipe
must stop between 2 in. (51
mm) above the top of the
chase and 4 3/4 in. (121
mm) below the top of the
chase.
2 in. (51 mm)
maximum
4 3/4 in. (121 mm)
maximum
Chase
• TS345/TS345P Square Termination Cap
Termination Cap
Collar
2 in. (51 mm)
Minimum Height
Chase Top
Chimney
Pipe
Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm).
Figure 9.7
Installing a TS345/TS345P Square Termination Cap
• TCT375 Terra Cotta Cap
Remove 2 screws
Termination Cap
from front & back
to lift the top off
Collar
2 in. (51 mm)
Minimum Height
Chase Top
Chimney
Pipe
Figure 9.8
Installing a TCT375 Terra Cotta Cap
Place waterproof sealer under
each flange of the termination
cap and on top of each screw
to help prevent leaks.
The last section of pipe must
stop between 2 in. (51 mm)
above the top of the chase and
4 3/4 in. (121 mm) below the
top of the chase.
2 in. (51 mm)
maximum
4 3/4 in. (121 mm)
maximum
Chase
Place waterproof sealer
under each flange of the
termination cap and on
top of each screw to
help prevent leaks.
The last section of pipe
must stop between 2 in.
(51 mm) above top of
chase and 4-3/4 in. (121
mm) below top of chase
2 in. (51 mm)
4-3/4 in. (121 mm)
Chase