5-4
VU RECEIVE ADJUSTMENT (CONTINUED)
ADJUSTMENT
ADJUSTMENT ITEM DISPLAY
51 VU12 BPF8 flat ( M)
VU12-flat
(continued)
52 VU12 BPF8 flat (L)
53 VU12 BPF8 flat (M1)
54 VU12 BPF8 flat (M2)
55 VU12 BPF8 flat (H)
56 VU12 PRE flat (40 M)
VU12-flat
(Preamp ON)
57 VU12 PRE flat (65 M)
58 VU12 PRE flat (105 M)
59 VU12 PRE flat (165 M)
60 VU12 PRE flat (260 M)
61 VU12 PRE flat (410 M)
62 VU12 PRE flat (500 M)
63 VU12 PRE flat (625 M)
64 VU12 PRE flat (749 M)
65 VU12 PRE flat (750 M)
66 VU12 PRE flat (925 M)
67 VU12 PRE flat (1099 M)
68 VU12 ATT 10dB flat (40 M)
VU12-flat
(ATT 10dB)
69 VU12 ATT 10dB flat (65 M)
70 VU12 ATT 10dB flat (105 M)
71 VU12 ATT 10dB flat (165 M)
72 VU12 ATT 10dB flat (260 M)
73 VU12 ATT 10dB flat (410 M)
74 VU12 ATT 10dB flat (625 M)
75 VU12 ATT 10dB flat (925 M)
76 VU12 ATT 20dB flat (40 M)
VU12-flat
(ATT 20dB)
77 VU12 ATT 20dB flat (65 M)
78 VU12 ATT 20dB flat (105 M)
79 VU12 ATT 20dB flat (165 M)
80 VU12 ATT 20dB flat (260 M)
81 VU12 ATT 20dB flat (410 M)
82 VU12 ATT 20dB flat (625 M)
83 VU12 ATT 20dB flat (925 M)
: The output level of the standard signal generator (SSG) is indicated as the SSG's open circuit.
CONDITION
• Set the test equipment to:
Frequency:
925.0215 MHz
• Set the test equipment to:
Frequency:
750.0215 MHz
• Set the test equipment to:
Frequency:
850.0215 MHz
• Set the test equipment to:
Frequency:
1020.0215 MHz
• Set the test equipment to:
Frequency:
1099.9815 MHz
• Set the test equipment to:
Frequency:
40.0215 MHz
• Set the test equipment to:
Frequency:
65.0215 MHz
• Set the test equipment to:
Frequency:
105.0215 MHz
• Set the test equipment to:
Frequency:
165.0215 MHz
• Set the test equipment to:
Frequency:
260.0215 MHz
• Set the test equipment to:
Frequency:
410.0215 MHz
• Set the test equipment to:
Frequency:
500.0215 MHz
• Set the test equipment to:
Frequency:
625.0215 MHz
• Set the test equipment to:
Frequency:
749.9815 MHz
• Set the test equipment to:
Frequency:
750.0215 MHz
• Set the test equipment to:
Frequency:
925.0215 MHz
• Set the test equipment to:
Frequency:
1099.9815 MHz
• Set the test equipment to:
Frequency:
40.0215 MHz
• Set the test equipment to:
Frequency:
65.0215 MHz
• Set the test equipment to:
Frequency:
105.0215 MHz
• Set the test equipment to:
Frequency:
165.0215 MHz
• Set the test equipment to:
Frequency:
260.0215 MHz
• Set the test equipment to:
Frequency:
410.0215 MHz
• Set the test equipment to:
Frequency:
625.0215 MHz
• Set the test equipment to:
Frequency:
925.0215 MHz
• Set the test equipment to:
Frequency:
40.0215 MHz
• Set the test equipment to:
Frequency:
65.0215 MHz
• Set the test equipment to:
Frequency:
105.0215 MHz
• Set the test equipment to:
Frequency:
165.0215 MHz
• Set the test equipment to:
Frequency:
260.0215 MHz
• Set the test equipment to:
Frequency:
410.0215 MHz
• Set the test equipment to:
Frequency:
625.0215 MHz
• Set the test equipment to:
Frequency:
925.0215 MHz
5-7
OPERATION
Touch [SET].
(A beep sounds, and then
another beeps sound 1
seconds later.)