Features - Carrier 40MPHB Owner's Manual

Ductless unit split system

Advertisement

40MPHB: Owner's Manual

FEATURES

The unit provides the following features for added comport and safety.
Time Delay
If ON/OFF is pressed too soon after a stop, the compressor will not start
for 3 to 4 minutes due to the inherent protection against frequent
compressor cycling. The unit only emits an audible beep when the signals
are received correctly.
Heating
If the unit is in HEATING mode, there is a delay when the fan starts. The
fan starts only after the coil is warmed up to prevent cold blow.
Auto Defrost Operation
In the HEATING mode, if the outdoor coil is frosted, the indoor fan and
outdoor fan turns off while the system removes the frost on the outdoor
coil. The system automatically reverts to normal operation when frost is
removed from the outdoor unit.
Auto Start
If the power fails while the unit is operating, the unit stores the operating
condition, and it will start operation automatically under those conditions
when the power is restored.
Auto-Restart (some units)
If the unit loses power, it automatically restarts with the prior settings
once power has been restored.
Anti-mildew (some units)
When turning off the unit from COOL, AUTO (COOL), or DRY modes,
the air conditioner continues to operate at very low power to dry up any
condensed water and prevent mildew growth.
Wireless Control (some units)
Wireless control allows users to control the air conditioner using a mobile
phone and a wireless connection. For the USB device access,
replacement, maintenance operations must be carried out by professional
staff.
Louver Angle Memory (some units)
When turning on the unit, the louver automatically resumes its former
angle.
Breeze Away (some units)
This feature avoids direct air flow from blowing on inhabitants.
Refrigerant Leak Detection (some units)
The indoor unit automatically displays EL0C when it detects refrigerant
leakage.
Occupancy Sensor
The system is controlled intelligently under the Occupancy Sensor
mode. The feature detects the movement in the room. In COOLING
mode, when occupants are away for 30 minutes, the unit automatically
lowers the frequency to save energy (for Inverter models only). And the
unit automatically starts and resumes operation when movement is
detected. This feature cannot be used in a multi-zone system.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Resetting the Remote Control
If the batteries in the remote control are removed, the current settings
cancel and the control returns to the initial settings and enters the
STANDBY mode. Push ON/OFF to activate.
NOTE: For multi-zone air conditioners, the following functions are
not available: ACTIVE CLEAN, SILENCE, BREEZE
AWAY, REFRIGERANT LEAKAGE DETECTION and
ECO.
Setting Vertical Angle of Air Flow
While the unit is on, press SWING on the remote control to initiate the
horizontal louver AUTO SWING feature.
NOTE: When using the COOL or DRY mode, do not set the louver at
too high of an angle for long periods of time. Doing so can
cause water to condense on the louver blade, which may drop
on your floor or furnishings. When using the COOL or
HEAT mode, setting the louver at too high of an angle can
reduce the performance of the unit due to restricted air flow.
Setting Horizontal Angle of Air Flow
When the unit is on, press and hold SWING for 2 seconds on the remote
control to initiate the vertical louver auto swing feature to control the
horizontal angle of the airflow.
ECO/Gear Function
Used to enter the ENERGY EFFICIENT mode and is only available in
the COOLING mode. When in COOLING mode, press ECO/GEAR,
the remote controller will maintain the temperature automatically
between 75°F and 86°F, and set the fan speed to Auto.
Operation time in the ECO mode is 8 hours. After 8 hours, or if a
conflicting setting is engaged, the air conditioner exits this mode.
Gear operation is engaged by cycling through the ECO/GEAR
operations. After ECO, there is a setting for up to 75% and 50% of the
unit's electrical consumption. The last step in the cycle is the previous
unit setting before ECO setting is engaged again and the cycle starts over.
9