Input Data (From Device To Master) - Siemens 7ME30 Instruction Manual

Sitrans f ultrasonic flowmeters with profibus pa interface
Table of Contents

Advertisement

Instruction Manual
4.1.1.1

Input Data (from device to master)

Input data are user data (measured values) which are transmitted from the device to the master in the
following format:
Every measured value consists of 5 bytes which are composed of a floating point value corresponding with
IEEE -- 754 (4 bytes) and the appropriate measured value status (1 byte). First the measured value and
then the corresponding status is transmitted in the PROFIBUS telegram.
Byte
No.
7 (MSB)
1
VZ
2
E
0
2
3
M
- -8
2
4
M
- -16
2
VZ: sign;
0 = positive, 1 = negative
Table 4--1
Measured value format
Byte
No.
7 (MSB)
5
Quality
Table 4--2
Status byte format
The status bytes consist of 3 components:
Quality
D
Substatus
D
Limits
D
The components can use the following values with SITRANS F:
Bit
Profile description
7
6
0
0
bad
0
1
uncertain
1
0
good (not cascade)
Table 4--3
Quality
12
6
5
E
E
7
6
2
2
M
M
- -1
- -2
2
2
M
M
- -9
- -10
2
2
M
M
- -17
- -18
2
2
6
5
(the maximum value bits 6 and 7):
(bit 2 to 5):
(the minimum bits 0 and 1):
Meaning
Measured value cannot be used
Measured value uncertain
Measured value o.k.
Bit
4
3
E
E
5
4
2
2
M
M
- -3
- -4
2
2
M
M
- -11
- -12
2
2
M
M
- -19
- -20
2
2
E: Exponent
Bit
4
3
Substatus
describes the basic quality of the
corresponding measured value
differentiates the quality of the
corresponding measured value
signal that limit values have been
exceeded
2
1
E
E
3
2
2
2
M
M
- -5
- -6
2
2
M
M
- -13
- -14
2
2
M
M
- -21
- -22
2
2
M: Mantissa
2
1
Limits
SITRANS F with PROFIBUS PA
C79000-B5676-C114-03
0 (LSB)
E
1
2
M
- -7
2
M
- -15
2
M
- -23
2
0 (LSB)