Grounding Ux115 Device - VeriFone UX115 Installation Manual

Table of Contents

Advertisement

For more details on the usage of the power supply, contact Verifone
representative. For cable ordering information, see
Documentation.
Grounding
When the UX115 device is connected to the UX300/UX301/UX410 controller, it is
UX115 Device
important to ground the units.
NOTE
For cable ordering information, see
1
2
Figure 7
3
NOTE
Tighten the nuts with a recommended torque of 5.0 kgf cm (0.49 Nm or 4.3 lbf in).
4
Remove a mounting nut, exposing a stud from the back of the UX115 device
(do not remove the cable retainer nut).
Attach the grounding cable (VPN WIR159-302-01-A) from the UX115 Device
to the UX300 and the grounding cable (VPN WIR159-302-02-A) from the
UX115 device to a ground installation.
Grounding UX115 device and UX300 Units
Tighten the nut to secure the UX115 device.
Remove a mounting nut, exposing a stud from the back of the UX300 unit.
Accessories and
Accessories and
Documentation.
Figure 7
See (A).
Figure 7
See (B).
A
C
S

Grounding UX115 Device

B
C
UX115 I
G
NSTALLATION
UIDE