4. Network Cable

Connector RJ45
Type
Cable
Category
Length
Limitation of NE3108-008
The width of the root portion of a plug should
Good
Twisted Pair Cable ( UTP / STP ) must be 4pair wiring.
Make sure you use cable that complies with the TIA-568 wiring
specification.
10BASE-T: Cat.3 or better,
100BASETX : Cat.5 or better
1000BASE-T Cat.5e or better
100 m (max.)
Cables connected to servers will charge static electricity by
friction against the floor. Use of static removal tool for cables is
recommended before connecting them to avoid servers from
destruction.
To prevent any damage on components due to static electricity, make
sure to discharge static electricity from yourself before you touch the
adapter.
Firmly connect the network cable
When connecting the cable, insert the cable connector until you hear a
click sound.
less than12mm
11.58~11.79mm
based on ISO standard.
use the cable within 12mm.
Bad
cable boots
- 24 -
Refer to the left figure
which does not get
used to use for the
cable with boots (with
a connector cover).
* The cable with boots
causes
of
poor
contact
and
a
connector breakage.