ipe-2200ax-T and
ipe-2200ax-F
Installation in a Rack
Installation in a Rack
An ipe-2200ax appliance is to be installed in a rack.
It is also possible to lay it on a table. Make sure it lays flat and it is stable.
Warning: whatever the method of installation used, do not obstruct the ventilation openings on the
front and rear panels of the case.
Choose a suitable location for the rack unit that will hold your appliance. It should be situated in a
clean, dust-free and well ventilated area. Avoid areas where heat, electrical noise and
electromagnetic fields are generated. You will also need it placed near a grounded power outlet.
Preparing for Setup
The box your chassis was shipped in should include two sets of rail assemblies, two rail mounting
brackets and the mounting screws you will need to install the system into the rack.
Please read this section in its entirety before you begin the installation procedure outlined in the
sections that follow.
Choosing a Setup Location
Leave enough clearance in front of the rack to enable you to open the front door completely
(~60 cm / 25 inches).
Leave approximately 75 cm / 30 inches of clearance in the back of the rack to allow for sufficient
airflow and ease in servicing.
This product is for installation only in a Restricted Access Location (dedicated equipment rooms,
service closets and similar environments).
Rack Precautions
Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the
full weight of the rack resting on them.
In single rack installation, stabilizers should be attached to the rack.
In multiple rack installations, the racks should be coupled together.
Always make sure the rack is stable before extending a component from the rack.
You should extend only one component at a time. Extending two or more simultaneously may
cause the rack to become unstable.

Advertisement

loading

Summary of Contents for Extreme Networks ipe-2200ax-T

  • Page 1 Installation in a Rack Installation in a Rack An ipe-2200ax appliance is to be installed in a rack. It is also possible to lay it on a table. Make sure it lays flat and it is stable.
  • Page 2: Rack Mounting Considerations

    – Installation in a Rack Appliance Precautions Review the electrical and general safety precautions that came with the components you are • adding to your chassis. • Determine the placement of each component in the rack before you install the rails.
  • Page 3: Assembling The Outer Rails

    – Installation in a Rack Assembling the Outer Rails Each outer rail comes in two sections that must be assembled before mounting onto the rack. Identify the left and right outer rails by examining the ends, which bend outward. Match the left front outer rail with the left rear outer rail and the same for the right rails.
  • Page 4: Installing The Outer Rails Onto The Rack

    – Installation in a Rack Installing the Outer Rails onto the Rack Each end of the assembled outer rail includes a bracket with square pegs to fit into your rack holes. If you have an older rack with round holes, these brackets must be removed, and you must use screws to secure the rail to the rack.
  • Page 5 – Installation in a Rack Note: the figure above is for illustrative purposes only. Always install servers at the bottom of the rack first. Warning: do not pick up the appliance with the front handles. They are designed to pull the system from a rack only.
  • Page 6 Copyright © 2022 Extreme Networks, Inc. All rights reserved. Legal Notice Extreme Networks, Inc. reserves the right to make changes in specifications and other information contained in this document and its website without prior notice. The reader should in all cases consult representatives of Extreme Networks to determine whether any such changes have been made.

This manual is also suitable for:

Ipe-2200ax-f