Download Print this page

Sealey STW901 Quick Start Manual page 3

Sq drive torque wrench micrometer style - calibrated series

Advertisement

Test machine type/name
Test machine serial No.
Test machine calibration date
2
Measurement error
Min Torque:
1
Max torque:
Tolerance ± 4 % of Test Load
Test
Test
%
Load
20%
5
60%
15
100%
25
Min Torque:
2
Max torque:
Test
Test
Tolerance ± 4 % of Test Load
%
Load
20%
0
60%
0
100%
0
Tool Model Number
Tool Serial Number
Tested by (print name)
4
Date of test
1
Notes:
Testing is in compliance with International Standard procedures, with test equipment calibrated by a
laboratory traceable to International Standards.
2
Measurement error shall be less than ¼ of the maximum permissible relative deviation of the torque
tool.
3
The observed values fall within the maximum permissible deviation (tolerance). For tools with a flexible
head, the result is valid only if the measuring axis is perpendicular to the axis of the tool.
4
This Sealey Declaration of Conformance is issued at the time of manufacture and its validity is open
ended until the torque tool is used for the first time. Unless otherwise stipulated, a period of 12 months,
or 5,000 cycles, whichever occurs first, may be taken as default values for the interval between
calibration checks. This period starts after first use of the torque tool.
clause 5.3 refers).
© Jack Sealey Limited
Declaration of Conformance
(in accordance with BS EN ISO 6789-1:2017)
TORQUE TESTER
17/07/2019
Min
Max
4.80
5.20
14.40
15.60
24.00
26.00
Min
Max
0.00
0.00
0.00
0.00
0.00
0.00
STW901
CALIBRATION CERTIFICATE
Measurement uncertainty
34406
Ambient temperature
Humidity
±1%
Test units: (Nm, lbf.ft, etc)
5
25
1
2
(This part 2 to be completed only where applicable)
1
2
TORQUE TOOL
1
Clockwise
Completed test reading
3
4
Anti-clockwise
Completed test reading
3
4
(BS EN ISO 6789-1:2017,
0.20%
26
52%
Nm
3
5
Average
3
5
Average
Issue 5 19/05/20

Advertisement

loading

This manual is also suitable for:

Stw900 seriesStw902Stw903Stw904Stw905Stw906 ... Show all