Check the SPI communication line.
YES
Check item(3-9.4.).
Check the SPI communication line :
Check the CPU.
Is the "SPI" waveform of the TP near the DSP [U1073] correct (like
the one shown in the diagram) when the power is turned on?
3 pin CLK
4 pin MOSI
6 pin CS
5 pin MISO
U1073
YES
NO
Check item(3-9.5.).
Check the SPI communication line :
Check DSP [U1073], CPU [U1018] patterns as well as soldering.
If there is no problem, go to the next step.
DSP [U1073] is faulty.
Replace with a new device.
Recheck from
check item (3.1.).
If it does not work, replace the PCB.
*The diagram shows an example.
(Signal patterns vary depending on the tim-
ing.)
Points for checking waveforms
- Crest value (3.3V normally)
- Signal change
- CLOCK frequency (about 6 MHz)
Voltage scale : 2.0V/div
Time scale : 2us/div