Sharp LC-32LE150M Service Manual page 18

Led backlight tv
Hide thumbs Also See for LC-32LE150M:
Table of Contents

Advertisement

LC-32LE150M
(18) Adjusted value is writing at [command]
MSET0003
(19) Set the G of point Max. to the default value
(4080 x G value of point 2 /
R2). Set the R,B
Max. value [G
– G value of point 2 + (R,B
max
value of point 2)
(20) Calculate the slope R2
G2
slope,
slope,
between MAX and Point2.
R2
(R
- R
)/(4080-3264)
slope =
max
high
(21) Calculate the correction value
R
G
B
high,
high,
high.
R
R2
(3561-3264)
high =
slope X
Set the reference value R,G,B of point 2
(22)
(R2 )=R2+ R
high
Calculate the slope R1
G1
(23)
slope,
between Point2 and Point1.
R1
(R
- R
)/(3264-816)
slope =
high
low
Calculate the correction value R
(24)
B
G
low,
low.
R
R1
(915-816)
low =
slope X
Set the reference value R,G,B of point 1
(25)
(R1 )=R1+ R
low
(26) Shut down the AC power.
Initial value at RGB 2 point : 3264
Initial value at RGB 1 point : 816
[Adjustment value]
Teaching set send by engineering dept is set as
reference.
[Reference values for adjustment reference]
Equipment : Luminance meter [Minolta CA-210]
Spec
Adjustment
Level
Data
Spec.
Point
x=0.270
+
-
2 ref.
204
0.0010
y=0.265
values
Point
x=0.270
+
-
1 ref.
51
0.0045
y=0.265
values
Ref. : For inspection, set the LCD TV as below.
AV MODE
: [DYNAMIC] (Reset)
Aging Time
: Minimum 5 minutes
B2
slope
B1
slope,
slope
low,
Inspection
Spec.
+
-
0.0020
+
-
0.0090
6 – 5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents