Error messages

Symptom or error
Unsupported memory.
Device address conflict.
Allocation error for device.
Failing bits: nnnn.
Invalid system configuration data.
I/O device IRQ conflict.
Hibernation error.
Fan error.
Thermal sensing error.
Authentication of system services failed.
Press <Esc> to resume.
Cannot boot from any device.
Symptom-to-FRU index
FRU or action, in sequence
DIMM. Make sure to use supported
memory.
1. Load "Setup Defaults" in the BIOS
Setup Utility.
2. Backup battery.
3. System board.
1. Load "Setup Defaults" in the BIOS
Setup Utility.
2. Backup battery.
3. System board.
1. DIMM.
2. System board.
1. DIMM.
2. System board.
1. Load "Setup Defaults" in the BIOS
Setup Utility.
2. Backup battery.
3. System board.
1. Restore the system configuration to
what it was before the computer
entered hibernation mode.
2. If memory size has been changed,
re-create the hibernation file.
1. Fan.
2. Thermal grease.
3. System board.
System board.
The Predesktop Area in the HDD is
corrupted. Restore it from a recovery CD.
Check the status of device which you want
to boot from.
Device not found.
1. The device you want to boot from.
2. System board.
Device Error.
1. The device you want to boot from.
2. System board.
No valid operating system.
1. Check that the operating system has no
failure and is installed correctly.
2. Reinstall the operation system.
Excluded from boot order.
v Enter the BIOS Setup Utility and add the
device in boot order.
Lenovo 3000 N100