    Operating instructions Electromechanical systems A-opener 2.1 Content INTRODUCTION .........4 Manufacturer and Service ......4 Target group of this documentation ..... 4 Intended use ..........4 1.3.1 Locking part and hardware ......4 1.3.2 Transport ............4 1.3.3 Opening/Closing/Locking ......4 Improper use ..........
  • Page 4: Introduction

    Electromechanical systems A-opener 2.1 Introduction multi-point lock with A-opener 2.1 is damaged, it must be replaced by KFV or repaired by a service Manufacturer and Service agent authorised by KFV. • Only KFV frame parts with Q adjustment may be KFV Karl Fliether GmbH &...
  • Page 5: Dimensions

    Operating instructions Electromechanical systems A-opener 2.1 • Never use cleaning agents that are aggressive or 1.7.2 Other types of indicators contain solvents. This could damage the surfaces of Below is a list of symbols used in these instructions and the components. their meanings: •...
  • Page 6 Operating instructions Electromechanical systems A-opener 2.1 The door leaf must not be carried using the lever hand- The lever handle and key must not be operated at the le as a grip. same time. None of the locking elements may be excluded when Double-leaf doors must not be forced open using the the door is open.
  • Page 7: Safety

    If energy-carrying cables are routed in parallel to data cables (ISDN, DSL, etc.), this could lead to interference e.g. in the speed of the data transmission. We recom- mend that you use the shielded KFV cable. See: Product catalogue KFV GENIUS and A-opener. H47.ELEKS005EN-00 02.2019...
  • Page 8: The Components Of The A-Opener

    Operating instructions Electromechanical systems A-opener 2.1 The components of the A-opener Connector pin assignment [1] Connections and function A-opener 2.1 for multi-point lock AS3500/3600 Connections Function Terminal A/B = Data interface SI-BUS Terminal C = A, B, C, D Output supply voltage – GND Terminal D = Output supply voltage + 24 V DC Operating voltage...
  • Page 9: Operation

    Operating instructions Electromechanical systems A-opener 2.1 Operation Menu handling Volume of the System services buzzer 100 % Couple device 75 % Disconnect device Log output (50 %) 25 % (Default settings) Long press: Press button 3 sec Retrieve menu: Press button 8 sec Short press: Press button 1 sec Magenta Black...
  • Page 10 Operating instructions Electromechanical systems A-opener 2.1 The three holding times The three different holding times are designated by Large arrow Large arrow Small arrow three different arrows in these instructions. black grey grey = 8 sec = 3 sec = 1 sec Change to level 2 main menu Press button (8 s).
  • Page 11 Operating instructions Electromechanical systems A-opener 2.1 Save and end When you have selected the desired setting, press "Button with menu - LED“ for 3 sec. This will save the setting. You will then proceed automatically to level 1. Ending without changes Wait for timeout (30 s).
  • Page 12: Set The Volume Of The Buzzer

    Operating instructions Electromechanical systems A-opener 2.1 Set the volume of the buzzer The buzzer delivers the acoustic feedback of the opening process or malfunction. The volume for the feedback of the opening process is adjustable in five stages from 0 % to 100 %. Coupled to this is the sound volume of the button of the menu LED with exception of the stage 0%.
  • Page 13: Call Up System Services

    Operating instructions Electromechanical systems A-opener 2.1 Call up system services The system services are mainly for the purpose of commissioning or service. Volume of the System services buzzer Couple device 100 % 75 % Disconnect device Log output (50 %) 25 % (Default settings) Long press: Press button 3 sec...
  • Page 14: Display Of Status Led

    Operating instructions Electromechanical systems A-opener 2.1 Display of status LED Buzzer Description Action Comments Green Disturbance-free Flashes Opening signal is present at green terminal 4. Flashes Faulty contact of the connec- Contact service partner if the Check connecting clamps yellow ting clamps fault persists Yellow...
  • Page 15: Technical Specifications

    Operating instructions Electromechanical systems A-opener 2.1 Technical specifications Environmental conditions Ambient temperature range in the door - 25 °C to + 70 °C (according to DIN EN 14846 class K,M,L,N,P) Relative humidity 20% to 80% (non-condensing) Protection class IP 40 Electrical data Operating voltage 24 V DC (19 V DC to 32 V DC)
  • Page 16: Test Report - Electromagnetic Compatibility

    Operating instructions Electromechanical systems A-opener 2.1 Test report - Electromagnetic compatibility 16/18 02.2019 H47.ELEKS005EN-00...
  • Page 17 Operating instructions Electromechanical systems A-opener 2.1 H47.ELEKS005EN-00 02.2019 17/18 17/18...