Refrigerant piping
• Install the refrigerant pipe securely during the installation
work before operating the air conditioner. If the compressor
is operated with the valve open and without refrigerant pipe,
the compressor sucks air and the refrigeration cycles is over
pressurized, which may cause a injury.
• Tighten the fl are nut with a torque wrench in the specifi ed
manner. Excessive tighten of the fl are nut may cause a crack in
the fl are nut after a long period, which may result in refrigerant
leakage.
• For installation and relocation work, follow the instructions in
the Installation Manual and use tools and pipe components
specifi cally made for use with R32 refrigerant. If pipe
components not designed for R32 refrigerant are used and the
unit is not installed correctly, the pipes may burst and cause
damage or injuries. In addition, water leakage, electric shock, or
fi re may result.
• Nitrogen gas must be used for the airtight test.
• The charge hose must be connected in such a way that it is not
slack.
11-EN
Electrical wiring
• Only a qualifi ed installer(*1) or qualifi ed service person(*1) is
allowed to carry out the electrical work of the air conditioner.
Under no circumstances must this work be done by an
unqualifi ed individual since failure to carry out the work properly
may result in electric shocks and/or electrical leaks.
• The appliance shall be installed in accordance with national
wiring regulations. Capacity shortages of the power circuit or an
incomplete installation may cause an electric shock or fi re.
• Use wiring that meets the specifi cations in the Installation
Manual and the stipulations in the local regulations and laws.
Use of wiring which does not meet the specifi cations may give
rise to electric shocks, electrical leakage, smoking and/or a fi re.
• Be sure to connect earth wire. (Grounding work)
Incomplete grounding causes an electric shock.
• Do not connect ground wires to gas pipes, water pipes, and
lightning rods or ground wires for telephone wires.
• After completing the repair or relocation work, check that the
ground wires are connected properly.
• Install a circuit breaker that meets the specifi cations in the
Installation Manual and the stipulations in the local regulations
and laws.
• Install the circuit breaker where it can be easily accessed by the
agent.
• When installing the circuit breaker outdoors, install one which is
designed to be used outdoors.
• Under no circumstances must the power cable be extended.
Connection trouble in the places where the cable is extended
may give rise to smoking and/or a fi re.
– 6 –