Technical Specification - Sullair SAR024 User Manual

Compressed air dryers
Table of Contents

Advertisement

Available languages

Available languages

KEY
1
By-pass Valve
2
Inlet Valve
3
Inlet Filter
4
By-pass Line
5
Outlet Valve
6
Outlet Filter
7
Outlet Sight Glass
8
Pressure Gauges
9
Control Box
10
Feed Line
(Optional with
Dewpoint
Dependent
Switching)

2. TECHNICAL SPECIFICATION

Type
Model
Operating flow range
Pressure Dewpoint:Nominal
Optional
Air quality : inc filtration (dirt. water. oil)
Maximum operating pressure
Minimum operating pressure
Maximum inlet temperature
Minimum inlet temperature
Regeneration
Nominal pressure drop across desiccant bed
Standard electrical supply ( ± 10% )
(Others on request)
Controls
Noise level
Desiccant
Material
Column
Inlet/Outlet head
Finish
Construction
Figure 1
4
7
1
2
IN
3
8
9
Heatless
SAR
14 cfm - 299 cfm ( 0.4m
o
o
-40
C (-40
F)
o
o
-70
C (-94
F)
ISO 8573.1 Class 1.2.1. Class 1.1.1
SAR024 to SAR088 16 Bar(g) (232 psig)
SAR106 to SAR175 13 Bar(g) (188 psig)
4 Bar(g) (58 psig)
o
o
50
C (122
F)
o
o
5
C ( 41
F)
Pressure Swing Adsorption (PSA)
140 mBar (g) (2 psi g)
230 VAC . 1phase. 50/60 Hz
110 VAC . 1phase. 50/60 Hz
Electronic Control Timer
<75 dB (A)
DRYFIL® ( Zeolite molecular sieve )
High tensile extruded aluminium.
Pressure die cast high tensile aluminium.
Alocrom anti-corrosion protection and dry powder
epoxy painted.
Column snow storm filled with desiccant material
and contained between the inlet and outlet head
using high tensile bolts.
2
5
6
10
3
3
/min - 8.47 m
/min )
Optional
OUT

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sar175