Page 2
AIR CARE SEMINAR TRAINING Sullair Air Care Seminars are courses that provide hands-on instruction for the proper operation, maintenance, and servicing of Sullair products. Individual seminars on Industrial compressors and compressor electrical systems are offered at regular intervals throughout the year at Sullair’s corporate headquarters training facility located at Michigan City, Indiana.
TABLE OF CONTENTS SECTION 1—INTRODUCTION SECTION 2—SAFETY SAFETY INFORMATION DEFINITION OF THE SAFETY SYMBOLS USED WARNINGS PROPER USE OF THE DRYER INSTRUCTIONS FOR THE USE OF PRESSURE EQUIPMENT SECTION 3—SPECIFICATIONS TYPE OF CONSTRUCTION AMBIENT CONDITIONS OPERATIONAL DATA PRESSURE VESSEL DESIGN AND CONSTRUCTION DATA PIPE MANIFOLD DETAILS ELECTRICAL DATA TIME, PRESSURE, TEMPERATURE, AND DEWPOINT SETTINGS...
Page 7
Follow all instructions carefully to ensure a trouble Sullair reserves the right to make changes or free life. modifications to the equipment designs without Our guarantee is affected if you fail to observe the notice.
Page 9
The equipment design, development, production, • Never weld on any pressure vessel or mod- assembly and customer service fall under the Sullair ify it in any way quality control system. • All maintenance on “pressure parts” must The dryer is state of the art.
Page 10
NOTES DEFINITION OF THE SAFETY SYMBOLS USED Before attempting any intervention on the dryer, read carefully the instructions reported in this use and maintenance manual. General warning sign. Risk of danger or possibility of damage to the machine. Read carefully the text related to this sign. Electrical hazard.
Page 11
SECTION 2 SAFETY—REGENERATIVE DRYERS Maintenance and/or control operation to be very carefully performed by qualified personnel 1. Compressed air inlet connection point. Compressed air outlet connection point. Condensate drain connection point. Operations which can be worked out by the operator of the machine, if qualified 1. NOTE Text to be taken into account, but not involving safety precautions.
SAFETY—REGENERATIVE DRYERS SECTION 2 WARNINGS Compressed air is a highly hazardous energy source. Never work on the dryer with parts under pressure. Never point the compressed air or the condensate drain jet towards anybody. The user is responsible for the installation of the dryer, which has to be executed on the basis of the instructions given in the “Installation”...
SECTION 2 SAFETY—REGENERATIVE DRYERS INSTRUCTIONS FOR THE 5. An internal inspection must be carried out at USE OF PRESSURE 12 month intervals to check for pressure EQUIPMENT equipment corrosion. The actual wall thick- ness of the tower after corrosion should not ensure safe operation...
DBP BLOWER PURGE HEATED DRYER SECTION 3 TYPE OF CONSTRUCTION 3.3.1 C OOLING • Designed for operation indoors in a Non- Medium Compressed air or ambient air hazardous location. The electrical equip- ment is constructed to Nema 12 standards. Nominal flow rate _____scfm •...
SECTION 3 DEX HEATED REGENERATIVE DRYER ELECTRICAL DATA DIMENSIONS AND WEIGHT Power Supply 480 volt, 3 phase, 60 Hz Width _____”inches Installed power _____KW Height _____”inches Electrical Encolsure NEMA 12 Depth _____”inches Control voltage 120 Volts A.C. Weight Approx. _____lbs Solenoid coil voltage 120 Volts A.C.
Page 19
DBP BLOWER PURGE HEATED DRYER Section 4 INSTALLATION The dryer should be installed on a level location that • Up to 20 feet long use one size bigger pipe. is selected to provide easy access to all parts of the •...
DBP BLOWER PURGE HEATED DRYER Section 5 OPERATION ADSORPTION provided by PLC temperature controller )Type K thermocouple). Compressed air flows through the system prefilter and into the bottom of the online desiccant chamber COOLING via the inlet switching valve and desiccant support screen.
DBP BLOWER PURGE HEATED DRYER SECTION 5 DEWPOINT CONTROLLED Prior to starting the regeneration the complete VESSEL CHANGE OVER installation should be checked over to verify the (OPTION) following points. 1. Are the connections to and from the system The vessel change over will be initiated by the PLC inlet and outlet made? Are the correct size control system when the timed adsorption phase for and pressure rated connections used?
SECTION 5 DBP BLOWER PURGE HEATED DRYER EQUIPMENT SHUT DOWN PLANNED SHUTDOWNS, RECOMMENDED COMPLETE The Dryer can essentially be shut down under any REGENERATION PROCESS (HEATING “emergency conditions” at any time in the cycle. It COOLING) PRIOR TO STOPPING THE DRYER. is advisable to be fully familiar with the dryer and its This ensures that the full heating and cooling cycle operation to avoid any possible hazard or injury as...
NOTES BLOWER SAFETY PRESSURE SWITCH, 1/4” NPT ALL DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED BLOWER INTAKE FILTER SILENCER MARK/TAG COMPONENT WITH SULLAIR PART NUMBER AND REVISION 2” NPT BLOWER-PURGE ADJUSTMENT GLOBE VALVE PAINT PER SULLAIR SPEC. 02250055-350 <NOT USED>...
Page 27
NOTES RANGE ALL DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED BLOWER SAFETY PRESSURE SWITCH, 1/4” NPT MARK/TAG COMPONENT WITH SULLAIR PART NUMBER AND REVISION BLOWER INTAKE FILTER SILENCER PAINT PER SULLAIR SPEC. 02250055-350 2” NPT BLOWER-PURGE ADJUSTMENT GLOBE VALVE <NOT USED>...
Page 31
BLOWER SAFETY PRESSURE SWITCH, 1/4” NPT NOTES BLOWER INTAKE FILTER SILENCER ALL DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED BLOWER-PURGE ADJUSTMENT VALVE MARK/TAG COMPONENT WITH SULLAIR PART NUMBER AND REVISION <NOT USED> PAINT PER SULLAIR SPEC. 02250055-350 POWER ON LIGHT, GREEN POWER OFF/ON SWITCH...
Page 33
NOTES BLOWER INTAKE FILTER SILENCER BLOWER ISOLATION VALVE ALL DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED <NOT USED> MARK/TAG COMPONENT WITH SULLAIR PART NUMBER AND REVISION POWER ON LIGHT, GREEN PAINT PER SULLAIR SPEC. 02250055-350 POWER OFF/ON SWITCH PLC DISPLAY...
Page 35
BLOWER INTAKE FILTER SILENCER NOTES: BLOWER ISOLATION VALVE ALL DIMNSIONS ARE IN INCHES UNLESS OTHERWISE NOTED. <NOT USED> MARK/TAG COMPONENT WITH SULLAIR PART NUMBER AND REVISION POWER ON LIGHT, GREEN PAINT PER SULLAIR SPEC. 02250055-350 POWER OFF/ON SWITCH PLC DISPLAY...
Page 39
5.16 WD—DBP 500 1. Wire Colors: D.C. Positive Wiring Color: Solid Blue D.C. Negative Wiring Color: White with Blue Stripe A.C. Hot Control Wiring Color: Solid Red A.C. Neutral Control Wiring Color: Solid White A.C. Power Wiring Color: Solid Black ‘K’...
Page 41
5.17 WD—DBP 650 1. Wire Colors: D.C. Positive Wiring Color: Solid Blue D.C. Negative Wiring Color: White with Blue Stripe A.C. Hot Control Wiring Color: Solid Red A.C. Neutral Control Wiring Color: Solid White A.C. Power Wiring Color: Solid Black ‘K’...
Page 43
5.18 WD—DBP 800 1. Wire Colors: D.C. Positive Wiring Color: Solid Blue D.C. Negative Wiring Color: White with Blue Stripe A.C. Hot Control Wiring Color: Solid Red A.C. Neutral Control Wiring Color: Solid White A.C. Power Wiring Color: Solid Black ‘K’...
Page 45
5.19 WD—DBP 1000 1. Wire Colors: D.C. Positive Wiring Color: Solid Blue D.C. Negative Wiring Color: White with Blue Stripe A.C. Hot Control Wiring Color: Solid Red A.C. Neutral Control Wiring Color: Solid White A.C. Power Wiring Color: Solid Black ‘K’...
Page 47
5.20 WD—DBP 1250 1. Wire Colors: D.C. Positive Wiring Color: Solid Blue D.C. Negative Wiring Color: White with Blue Stripe A.C. Hot Control Wiring Color: Solid Red A.C. Neutral Control Wiring Color: Solid White A.C. Power Wiring Color: Solid Black ‘K’...
Page 49
5.21 WD—DBP 1500 1. Wire Colors: D.C. Positive Wiring Color: Solid Blue D.C. Negative Wiring Color: White with Blue Stripe A.C. Hot Control Wiring Color: Solid Red A.C. Neutral Control Wiring Color: Solid White A.C. Power Wiring Color: Solid Black ‘K’...
Page 51
5.22 WD—DBP 2000 1. Wire Colors: D.C. Positive Wiring Color: Solid Blue D.C. Negative Wiring Color: White with Blue Stripe A.C. Hot Control Wiring Color: Solid Red A.C. Neutral Control Wiring Color: Solid White A.C. Power Wiring Color: Solid Black ‘K’...
Page 53
5.23 WD—DBP 2500 1. Wire Colors: D.C. Positive Wiring Color: Solid Blue D.C. Negative Wiring Color: White with Blue Stripe A.C. Hot Control Wiring Color: Solid Red A.C. Neutral Control Wiring Color: Solid White A.C. Power Wiring Color: Solid Black ‘K’...
Page 55
5.24 WD—DBP 3000 1. Wire Colors: D.C. Positive Wiring Color: Solid Blue D.C. Negative Wiring Color: White with Blue Stripe A.C. Hot Control Wiring Color: Solid Red A.C. Neutral Control Wiring Color: Solid White A.C. Power Wiring Color: Solid Black ‘K’...
Page 57
5.25 WD—DBP 3500 1. Wire Colors: D.C. Positive Wiring Color: Solid Blue D.C. Negative Wiring Color: White with Blue Stripe A.C. Hot Control Wiring Color: Solid Red A.C. Neutral Control Wiring Color: Solid White A.C. Power Wiring Color: Solid Black ‘K’...
Page 59
5.26 WD—DBP 4000 1. Wire Colors: D.C. Positive Wiring Color: Solid Blue D.C. Negative Wiring Color: White with Blue Stripe A.C. Hot Control Wiring Color: Solid Red A.C. Neutral Control Wiring Color: Solid White A.C. Power Wiring Color: Solid Black ‘K’...
Page 61
5.27 WD—DBP 5000 1. Wire Colors: D.C. Positive Wiring Color: Solid Blue D.C. Negative Wiring Color: White with Blue Stripe A.C. Hot Control Wiring Color: Solid Red A.C. Neutral Control Wiring Color: Solid White A.C. Power Wiring Color: Solid Black ‘K’...
Page 63
5.28 WD—DBP 6000 1. Wire Colors: D.C. Positive Wiring Color: Solid Blue D.C. Negative Wiring Color: White with Blue Stripe A.C. Hot Control Wiring Color: Solid Red A.C. Neutral Control Wiring Color: Solid White A.C. Power Wiring Color: Solid Black ‘K’...
Page 65
5.29 WD—DBP 7000 1. Wire Colors: D.C. Positive Wiring Color: Solid Blue D.C. Negative Wiring Color: White with Blue Stripe A.C. Hot Control Wiring Color: Solid Red A.C. Neutral Control Wiring Color: Solid White A.C. Power Wiring Color: Solid Black ‘K’...
Page 67
5.30 WD—DBP 8000 1. Wire Colors: D.C. Positive Wiring Color: Solid Blue D.C. Negative Wiring Color: White with Blue Stripe A.C. Hot Control Wiring Color: Solid Red A.C. Neutral Control Wiring Color: Solid White A.C. Power Wiring Color: Solid Black ‘K’...
Page 69
5.31 WD—DBP 9000 1. Wire Colors: D.C. Positive Wiring Color: Solid Blue D.C. Negative Wiring Color: White with Blue Stripe A.C. Hot Control Wiring Color: Solid Red A.C. Neutral Control Wiring Color: Solid White A.C. Power Wiring Color: Solid Black ‘K’...
Page 71
5.32 WD—DBP 10000 1. Wire Colors: D.C. Positive Wiring Color: Solid Blue D.C. Negative Wiring Color: White with Blue Stripe A.C. Hot Control Wiring Color: Solid Red A.C. Neutral Control Wiring Color: Solid White A.C. Power Wiring Color: Solid Black ‘K’...
DBP BLOWER PURGE HEATED DRYER Section 6 TROUBLESHOOTING Symptom Probable Cause Remedy High humidity alarm (with The regeneration of the desiccant Reset the alarm with the “Alarm Reset” optional dew point monitor) beds is insufficient. push button. Verify the heating and cooling operations by observing regenerations.
Page 74
DBP BLOWER PURGE HEATED DRYER SECTION 6 Symptom Probable Cause Remedy Vessel #2 Re-pressurization The re-pressurization valve did not Check the pilot solenoid valve for correct open. operation. Check the valve actuator for correct operation. Vessel re-pressurized but the Check pressure switch PSH-2 for correct alarm is on.
DBP BLOWER PURGE HEATED DRYER Section 7 SYSTEM MAINTENANCE WITH YOUR DRYER ONLINE • Replace seats and shaft seals on all ball valves. The following points must be verified at regular • Dismantle the double acting pneumatic intervals actuators. Inspect internal components for visual signs of wear and replace parts as •...
DBP BLOWER PURGE HEATED DRYER Section 8 TECHNICAL DESCRIPTION OF COMPONENTS VALVES Basic devices used in the dryer system are described in this section. For more detailed additional information refer to the component bulletins included Inlet valves are Piston type Bronze valves, dryers up in the rear of this manual.
Page 80
SPARE PARTS LIST DBP Series Blower purge Dryers 02250194-366-XXX Applicable Model Number DBP-XXXXx 0500 0650 0800 1000 1250 1500 2000 2500 3000 3500 4000 5000 6000 7000 8000 9000 10000 Part Description Part Number Pilot Air Filter Element 02250193-577 PLC Siemens...
Page 81
DBP Series Blower purge Dryers 02250194-366-XXX Applicable Model Number DBP-XXXXx 0500 0650 0800 1000 1250 1500 2000 2500 3000 3500 4000 5000 6000 7000 8000 9000 10000 Part Description Part Number Lbs of Desiccant NACF-200-316 1000 1250 1562 1900 2500...
Page 82
DBP Series Blower purge Dryers 02250194-366-XXX Applicable Model Number DBP-XXXXx 0500 0650 0800 1000 1250 1500 2000 2500 3000 3500 4000 5000 6000 7000 8000 9000 10000 Part Description Part Number Outlet Check Valve (8") NOR8150WSSSV Ourge Check Valve (2") NSCY-200 Purge Check Valves (3")
Page 84
Always air. Always there. WWW.SULLAIR.COM SULLAIR CORPORATION 3700 East Michigan Boulevard • Michigan City, Indiana, 46360 U.S.A. Telephone: 1-219-879-5451 Printed in the U.S.A. Specifications subject to change without prior notice. E11EP...