Section 12. Electrical - High Voltage - Trane 4TWX8 Installer's Manual

Table of Contents

Advertisement

Defrost Termination Temperatures
Outdoor
Temperature
>22°F
As
10°F–22°F
Shipped
6°F–10°F
>30°F
Cut
Jumper 2
6°F–30°F
All

Section 12. Electrical - High Voltage

12.1 High Voltage Power Supply
WARNING
s
s
LIVE ELECTRICAL COMPONENTS!
During installation, testing, servicing, and
troubleshooting of this product, it may be nec-
essary to work with live electrical components.
Failure to follow all electrical safety precau-
tions when exposed to live electrical compo-
nents could result in death or serious injury.
The high voltage power supply must agree with
the equipment nameplate.
Power wiring must comply with national, state,
and local codes.
Follow instructions on unit wiring diagram located
on the inside of the control box cover and in the
Service Facts document included with the unit.
12.2 High Voltage Disconnect Switch
Install a separate disconnect switch at the
outdoor unit.
For high voltage connections, flexible electri-
cal conduit is recommended whenever vibra-
tion transmission may create a noise problem
within the structure.
18-BC91D1-6B-EN
Termination
Temperature
47°F
ODT + 25°F
35°F
47°F
70°F
12 min. or 35°F
< 6°F
every 3 hrs.
Defrost Board
Detail
JUMPER 2
TEST PINS
J1
J2
J3
FRC_DFT
U1
TST
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

4twx8024a4twx8036c4twx8048a4twx8060a

Table of Contents