Fujitsu ABHG54KRTA Service Manual page 32

Table of Contents

Advertisement

1. Error code ....................................................................................................03-1
1-1. Error code table (Wired remote controller)......................................................................03-1
1-2. Error code table (Outdoor unit) .......................................................................................03-2
2. Troubleshooting with error code ...............................................................03-4
2-1. E: 11. Serial communication error (Serial reverse transfer error) (Outdoor unit).............03-4
2-2. E: 11. Serial communication error (Serial forward transfer error) (Indoor unit) ...............03-6
2-3. E: 12. Wired remote controller communication error (Indoor unit) ..................................03-8
2-4. E: 15. Automatic air flow adjustment error (Indoor unit)..................................................03-9
2-5. E: 22. Indoor unit capacity error (Indoor unit) ...............................................................03-10
2-6. E: 23. Combination error (Outdoor unit)........................................................................03-11
2-7. E: 32. Indoor unit main PCB error (Indoor unit) ............................................................03-12
2-8. E: 33. Indoor unit motor electricity consumption detection error (Indoor unit) ...............03-13
2-9. E: 35. MANUAL AUTO button error (Indoor unit)..........................................................03-14
2-10. E: 39. Indoor unit power supply error for fan motor (Indoor unit) ................................03-15
2-11. E: 41. Room temperature sensor error (Indoor unit) ...................................................03-16
2-12. E: 42. Indoor unit heat exchanger sensor error (Indoor unit) ......................................03-17
2-13. E: 51. Indoor unit fan motor error (Indoor unit) ...........................................................03-18
2-14. E: 53. Drain pump error (Indoor unit) ..........................................................................03-19
2-15. E: 62. Outdoor unit main PCB error (Outdoor unit) .....................................................03-20
2-16. E: 63. Inverter error (Outdoor unit)..............................................................................03-21
2-17. E: 64. PFC circuit error (Outdoor unit) ........................................................................03-22
2-18. E: 65. Trip terminal L error (Outdoor unit)...................................................................03-23
2-19. E: 71. Discharge thermistor error (Outdoor unit).........................................................03-24
2-20. E: 72. Compressor thermistor error (Outdoor unit) .....................................................03-25
2-21. E: 73. Heat exchanger (Middle/Outlet) temperature thermistor error (Outdoor unit) ...03-26
2-22. E: 74. Outdoor temperature thermistor error (Outdoor unit)........................................03-27
2-23. E: 77. Heat sink thermistor error (Outdoor unit) ..........................................................03-28
2-24. E: 84. Current sensor error (Outdoor unit) ..................................................................03-29
2-25. E: 86. High pressure switch error (Outdoor unit) ........................................................03-30
2-26. E: 86. High pressure switch error (Outdoor unit) ........................................................03-31
2-27. E: 94. Trip detection (Outdoor unit).............................................................................03-32
2-28. E: 95. Compressor motor control error (Outdoor unit) ................................................03-33
2-29. E: 97. Outdoor unit fan motor error (Outdoor unit) ......................................................03-34
2-30. E: 99. 4-way valve error (Outdoor unit).......................................................................03-35
2-31. E: A1. Discharge temperature error (Outdoor unit) .....................................................03-37
2-32. E: A3. Compressor temperature error (Outdoor unit)..................................................03-39
2-33. E: AC. Heat sink temperature error (Outdoor unit)......................................................03-41
3. Troubleshooting without error code........................................................03-42
3-1. Indoor unit—No power..................................................................................................03-42
3-2. Outdoor unit—No power...............................................................................................03-43
3-3. No operation (Power is on) ...........................................................................................03-44
3-4. No cooling/No heating ..................................................................................................03-45
CONTENTS
3. TROUBLESHOOTING

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aohg54krta

Table of Contents