LG LMU365HV Specifications page 29

Lg lmu365hv: user guide
Table of Contents

Advertisement

OUTDOOR UNITS H/P INVERTER
24,000 BTUs
LMU185HV
Dual-Zone
LMU245HV
Tri-Zone
LMU365HV
Quad-Zone
FEATURES:
Defrost /Deicing
Restart delay (3-minutes)
Self diagnosis
Soft start
Test function
Outdoor Model H/P Inverter #
Capacity
Input
(Min.~Rated~Max.)
Running Current (Rated)
Power Supply
Power Supply Cable (Outdoor) —
Power and Transmission Cable —
(Outdoor to Indoor unit )
Dimensions (W x H x D)
Net Weight
Max. # of Connectable
Indoor Units
Refrigerant
Sound Level (H/L)
Piping Connections
Piping length spec.
Max. Elevation Difference
Operation Range
(Outdoor)
*Note :
1. Capacities are based on the following conditions:
Cooling: - Indoor Temperature 80ºF (26.7ºC ) DB/67ºF (19.4ºC) WB
- Outdoor Temperature 95ºF (35ºC) DB/75ºF (23.9ºC) WB
Heating: - Indoor Temperature 70ºF (21.1ºC) DB/60ºF (15.6ºC) WB
- Outdoor Temperature 47ºF (8.3ºC) DB/43ºF (6.1ºC) WB
Piping Length: - Interconnecting Piping Length 24.6 ft.(7.5m)
- Level Difference of Zero
Auto operation (Artificial intelli-
gence)
Auto restart operation
Low ambient operation
Gold Fin™ Anti-Corrosion
Cooling
kW
Heating
kW
Cooling
A
Heating
A
Ø / V / Hz
No. x AWG
No. x AWG
inch
lbs
Charge (at 24.6 ft.)
oz
Type
Control
Sound Pressure
dB(A)+3
Liquid
inch
Gas
inch
Max. total piping
ft.
Max. OD~ID piping
ft.
Chargeless piping
ft.
Outdoor Unit~Indoor Unit
ft.
Indoor Unit~Indoor Unit
ft.
Cooling
˚F
Heating
˚F
DUAL-ZONE
TRI-ZONE
LMU185HV
LMU245HV
Exterior Unit Includes:
Exterior unit
Sufficient refrigerant for charg-
ing 2, 3 or 4 indoor coils
& 25' line set per indoor unit
(line set not included)
LMU185HV
18,000 BTU/h Class
0.52~1.26~2.05
0.77~1.63~2.18
2.3~5.7~9.5
3.4~7.2~9.6
1/208~230/60
14/2
4 x 18
34.3x25.8x12.6
115
2
59.97
R410A
EEV
51/45
1/4 x 2EA
3/8 x 2EA
164.0
82.0
73.8
49.2
24.6
14 ~114.8
5~ 75.2
2. Wiring cable size must comply with the applicable local and national code.
3. The specification may be subject to change without prior notice for purpose of
improvement.
4. For more capacity(*) information, refer to the combination tables.
5. The data mentioned in the above table are only for non-ducted type of indoor unit.
QUAD-ZONE
LMU365HV
LMU245HV
LMU365HV
24,000 BTU/h Class
36,000 BTU/h Class
0.72~1.98~3.27
0.72~3.21~3.92
0.72~2.86~3.5
0.72~3.7~4.10
3.0~8.8~14.5
3.0~14.2~17.3
4.5~12.4~15.5
4.5~16.3~18.5
1/208~230/60
1/208~230/60
12/2
12/2
4 x 18
4 x 18
34.3x31.8x12.6
34.3x31.8x12.6
143.3
143.3
3
4
89.95
89.95
R410A
R410A
EEV
EEV
52
52
1/4 x 3EA
1/4 x 4EA
3/8 x 3EA
3/8 x 4EA
246.1
246.1
82.0
82.0
123.0
123.0
49.2
49.2
24.6
24.6
14 ~114.8
14 ~114.8
5~ 75.2
5~ 75.2
26