D. Install Cooling Air Hoods (PROVIDED)
WARNING!
Cooling air must be provided when install-
ing in combustible enclosure or on combustible surface.
•
Locate cooling air hoods to prevent blockage from
leaves, snow/ice, or other debris. Blockages could
cause the unit to overheat.
•
The lowest point of the cooling air hoods to be located
a minimum of 12" above the bottom of unit.
•
Do Not place cooling air hood close to exhaust vent.
•
Cut a 4 in. hole in the enclosure for the hood.
•
The outside air hood can be painted to match/accent
the color of the structure.
•
An air grille can be used in place of the plastic hoods
(Provided); Grill MUST have a minimum of 25 sq/
in opening to allow for proper cooling air flow to unit.
Lowest edge of grille to be located a minimum of 12"
above the bottom of the unit
Caution
! Risk of Fire or Asphyxiation! Do not draw
outside air from wall, floor, or ceiling cavity, or enclosed
spaces such as an attic or garage.
22
Outdoor Lifestyles by Hearth & Home Technologies Inc.• 4072-203 Rev A • 08/18
Figure 7.3 Cooling Air Hood