Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 °F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
COIL MULTIPLIERS - 3 TON
Air Handler
Coil
—
CF/CM/CU36B
—
CF/CM48D
—
CF/CM60D
—
XAF/XAUB36D
—
XAF/XAUC48F
—
XAF/XAUC60G
—
XAF/XAUD60G
—
XAFC36D
—
XAFC60H
—
XAFD48F
—
XAHC36D
—
XAHC48F
—
XAHC60G
—
XAHC60H
—
XAHD48F
—
XAHD60G
—
XAHD60H
—
CF/CM/CU36C
—
CF/CM/CU42C
—
CF/CM/CU48C
—
CF/CM/CU60C
—
CF/CM64D
AE36BX21
AE36CX21
AE42CX21
AE48CX21
AE48DX21
AE60DX21
AVC36BX21
AVC36CX21
AVC42CX21
AVC48CX21
AVC48DX21
AVC60CX21
AVC60DX21
ME12BN21
CF/CM36B
ME12BN21
CF42B
ME12CN21
CF/CM36C
ME14DN21
CF/CM36D
ME14DN21
CF/CM42D
ME14DN21
CF/CM48D
ME14DN21
CF/CM60D
ME14DN21
CF/CM64D
ME16CN21
CF/CM36C
ME16CN21
CF/CM42C
ME16CN21
CF/CM48C
ME16CN21
CF/CM60C
MVC08BN21
CF/CM36B
MVC08BN21
CF42B
MVC12BN21
CF/CM36B
MVC12BN21
CF42B
MVC12CN21
CF/CM36C
Johnson Controls Ducted Systems
T.C.
S.C.
0.97
0.95
0.98
0.97
0.98
0.96
0.98
0.96
0.98
0.97
0.99
0.98
0.99
0.98
0.98
0.96
0.99
1.00
0.98
0.97
0.98
0.96
0.98
0.97
0.99
0.98
0.99
1.00
0.98
0.97
0.99
0.98
0.99
1.00
0.96
1.07
0.97
1.07
0.97
1.08
0.99
1.06
1.00
1.00
—
0.98
1.05
—
0.98
1.09
—
0.99
1.09
—
1.00
1.12
—
1.00
1.15
—
1.00
1.13
—
0.97
1.06
—
0.98
1.11
—
1.00
1.12
—
1.00
1.10
—
1.00
1.15
—
1.00
1.07
—
1.00
1.05
0.98
1.10
0.98
1.02
0.98
1.11
0.98
1.09
0.99
1.10
0.99
1.11
1.00
1.07
1.00
1.13
0.98
1.04
1.00
1.13
1.00
1.14
1.00
1.14
0.96
1.00
0.97
0.99
0.98
1.05
0.99
1.12
0.98
1.09
COIL MULTIPLIERS - 3 TON (Continued)
Air Handler
KW
MVC12CN21
1.01
MVC12CN21
1.02
MVC12CN21
1.04
MVC14DN21
0.99
MVC14DN21
1.00
MVC14DN21
1.05
MVC14DN21
1.05
MVC14DN21
0.99
MVC16CN21
1.05
MVC16CN21
1.00
MVC16CN21
0.99
MVC16CN21
1.00
MVC20DN21
1.05
MVC20DN21
1.05
MVC20DN21
1.00
MVC20DN21
1.05
1.05
FURNACE MULTIPLIERS - 3 TON
0.94
Furnaces
0.97
TL8E060A12UH11
0.97
TL8E060A12UH11
0.99
TL8E060A12UH11
1.00
TL8E060A12UH11
0.92
TL8E080C16UH11
0.89
TL8E080C16UH11
0.90
TL8E080C16UH11
0.91
TL8E080C16UH11
0.91
TL8E080C16UH11
0.91
TL8E080C16UH11
0.92
TL8E080C16UH11
0.91
TL8E080C16UH11
0.92
TL8E080C16UH11
0.91
TL8E080C16UH11
0.91
TL8E080C16UH11
0.92
TL8E080C16UH11
0.91
TL8E080C16UH11
0.92
TL8E080C16UH11
0.90
TL8E080C16UH11
0.91
TL8E080C16UH11
0.89
TL8E080C16UH11
0.90
TL8E080C16UH11
0.90
TL8E080C16UH11
0.91
TL8E080C16UH11
0.91
TL8E080C16UH11
0.90
TL8E080C16UH11
0.92
TL8E080C16UH11
0.92
TL8E100C20UH11
0.92
TL8E100C20UH11
0.94
TL8E100C20UH11
0.95
TL8E100C20UH11
0.90
TL8E100C20UH11
0.94
TL8E100C20UH11
0.91
TL8E100C20UH11
5545023-YTG-G-1121
Coil
T.C.
CF/CM42C
0.97
CF/CM48C
0.98
CF/CM60C
1.00
CF/CM36D
0.99
CF/CM42D
1.00
CF/CM48D
1.00
CF/CM60D
1.00
CF/CM64D
1.00
CF/CM36C
0.99
CF/CM42C
1.00
CF/CM48C
1.00
CF/CM60C
1.00
CF/CM36D
0.99
CF/CM42D
1.00
CF/CM48D
1.00
CF/CM64D
1.00
Coil
T.C.
CF/CM/CU36B
0.96
CF42B
0.96
XAF/XAUB36D
0.97
XAHB36D
0.97
CF/CM/CU36C
0.98
CF/CM/CU42C
0.98
CF/CM/CU48C
0.98
CF/CM/CU48D
0.98
CF/CM/CU60C
0.98
CF/CM/CU60D
1.00
CF/CM36D
0.98
CF/CM42D
0.98
CF/CM64D
1.00
XAF/XAUC48F
0.99
XAF/XAUC60G
0.99
XAF/XAUD60G
1.01
XAF/XAUD60H
1.01
XAFC36D
0.99
XAFC60H
1.01
XAFD48F
0.99
XAHC36D
0.98
XAHC48F
0.99
XAHC60G
0.99
XAHC60H
1.01
XAHD48F
0.99
XAHD60G
0.99
XAHD60H
1.01
CF/CM/CU36C
0.98
CF/CM/CU42C
0.99
CF/CM/CU48C
1.00
CF/CM/CU48D
1.00
CF/CM/CU60C
1.00
CF/CM/CU60D
1.00
CF/CM36D
0.99
S.C.
KW
0.99
0.88
1.01
0.89
1.08
0.91
1.13
0.90
1.14
0.88
1.15
0.91
1.14
0.88
1.14
0.88
1.13
0.92
1.14
0.91
1.14
0.91
1.14
0.91
1.13
0.90
1.12
0.88
1.16
0.88
1.13
0.88
S.C.
KW
1.01
0.92
0.99
0.92
0.92
1.01
0.89
1.00
1.05
0.92
1.05
0.91
1.06
0.91
1.06
0.91
1.05
0.92
1.08
0.94
1.05
0.92
1.05
0.91
1.05
0.91
0.98
0.99
1.00
1.01
1.01
1.02
1.02
0.99
0.98
1.01
1.06
1.01
0.98
0.99
0.92
1.00
0.98
0.99
1.00
1.01
1.07
1.01
0.98
0.99
0.95
1.01
1.06
0.99
1.12
0.91
1.11
0.92
1.12
0.91
1.10
0.91
1.07
0.92
1.07
0.92
1.12
0.93
149