  • Page 1 DRAGON™ Reference Manual DLL6000-R/OM6010-R Compatibility AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 Web : http: www.audin.fr - Email : info@audin.fr...
  • Page 2 Web : http: www.audin.fr - Email : info@audin.fr...
  • Page 3 DRAGON™ REFERENCE MANUAL DLL6000-R/OM6010-R COMPATIBILITY Web : http: www.audin.fr - Email : info@audin.fr...
  • Page 4 ALL RIGHTS RESERVED Datalogic reserves the right to make modifications and improvements without prior notification. Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor for incidental or consequential damages resulting from the use of this material.
  • Page 5: Table Of Contents

    CONTENTS HOW TO USE THIS MANUAL ............vi INITIAL SETUP.................. 1 Set Compatibility................. 1 DLL6000-R/OM6010-R Compatibility SetUp........2 1.2.1 Using Multiple Guns With Same Cradle..........5 1.2.2 Gun Default Configuration..............6 1.2.3 Cradle Default Settings ..............7 CONFIGURATION ................8 RS232 PARAMETERS..............
  • Page 6 3.4.3 Output Data Format................59 Header/Terminator Selection............60 Gun/Cradle Address Stamping ............61 Gun/Cradle Address Delimiter ............61 Time Stamping Format ..............61 Time Stamping Delimiter ...............61 Code Identifier ................62 Reading Parameters ................ 62 3.5.1 Trigger Signal ................... 62 3.5.2 Trigger Timeout................63 3.5.3 Reads per Cycle ................
  • Page 7: How To Use This Manual

    HOW TO USE THIS MANUAL This volume was written for the sole purpose of providing complete configuration for DRAGON™ M readers and OM-DRAGON™ cradles used as DLL6000-R/OM6010-R compatible readers and cradles for existing DLL6000-R/OM6010-R applications. If you are not using these products as DLL6000-R/OM6010-R compatible readers/cradles, then use the Standard Reference Manual for configuration.
  • Page 8 Reference notes describing the operation of the more complex parameters are given in chapter 3. For communication between Host and gun, refer to chapter 4. DL Sm@rtSet DL Sm@rtSet is a Windows-based utility program providing a quick and user-friendly configuration method via the RS232 interface. It also allows upgrading the software of the connected device (see the DL Sm@rtSet User's Manual for more details).
  • Page 9: Initial Setup

    The reader will automatically be switched off and restarted and four high tones will be emitted. At this point, the DRAGON™ M scanner is ready to be configured using the DLL6000-R procedure in par. 1.2. To restore the DRAGON™ M standard configuration read the following code, then follow the DRAGON™...
  • Page 10: Dll6000-R/Om6010-R Compatibility Setup

    DLL6000-R/OM6010-R COMPATIBILITY 1.2 DLL6000-R/OM6010-R COMPATIBILITY SETUP When the cradle is connected and powered, configure the gun by reading the following codes in the given sequence and follow the instructions. Note: Open the folded page at the end of this Manual for the Numeric code selections.
  • Page 11 INITIAL SETUP Exit and Save configuration G c C g C m C g C j G g C g G c J g G c G j G c G j Jc C c G Read the Bind code to pair the DLL6000-R to the OM6010-R: The reader is dedicated to the cradle.
  • Page 12 DLL6000-R/OM6010-R COMPATIBILITY Read the Interface Selection code for your particular application: RS232 Interface G c C g C m C g C j G g G j C g C g C j C j G c J c J c G c C g J c G g C g C j G g C g G c J g C g C j G g G j Jc C c G PEN EMULATION Interface G c C g C m C g C j G g G j C g C g C j C j G c J c J c G c G g J c C g C g C j G g C g G c J g C j C c G j G j Jc C c G...
  • Page 13: Using Multiple Guns With Same Cradle

    INITIAL SETUP Test C g C c G c G c C c G c C g C c C c G c C c G g C c C c G c G c G g C c C c C c C c C g G c C c G c G c C g G c C c C c C c G g G c C c C c C g C c G c G c C c 123456 Test O.K.: two short beeps...
  • Page 14: Gun Default Configuration

    DLL6000-R/OM6010-R COMPATIBILITY 1.2.2 Gun Default Configuration Reading Parameters Trigger Signal level Trigger Timeout 10 sec. Reads per Cycle Safety Time .5 sec Single-Store disabled Power-off Timeout 8 hours Beeper Intensity high Beeper Tone Good Transmission Beep enabled Decoding Parameters Ink Spread enabled Overflow Control enabled...
  • Page 15: Cradle Default Settings

    INITIAL SETUP 1.2.3 Cradle Default Settings RS232 Parameters Baud Rate 9600 Parity disabled Data Bits Stop Bit Handshaking disabled Radio RX Lock disabled Inter-character Delay disabled Rx Timeout 5 sec. Pen Emulation Parameters Conversion to Code 39 and Conversion to Code 39 Code 128 Output Level normal...
  • Page 16: Configuration

    DLL6000-R/OM6010-R COMPATIBILITY 2 CONFIGURATION The DLL6000-R and OM6010-R default parameters can be changed by following the procedure below. 1. Open the folded page in Appendix C with the Hex-Numeric table and keep it open during configuration. 2. Go to the section of the group to modify. 3.
  • Page 17 CRADLE PARAMETERS Web : http: www.audin.fr - Email : info@audin.fr...
  • Page 18: Rs232 Parameters

    RS232 PARAMETERS PARAMETERS DEFAULT BAUD RATE 9600 PARITY disabled DATA BITS STOP BITS HANDSHAKING disabled disabled RADIO RX LOCK disabled INTER-CHARACTER DELAY 5 sec. RX TIMEOUT TO CHANGE THE DEFAULT VALUES Read the Enter Configuration code ONCE, available at the top of each page. Read configuration codes from the desired groups = Choose only one code from each selected group = Follow the procedure given for this code group...
  • Page 19 Enter configuration Exit & Save configuration RS232 BAUD RATE 150 baud G c C g C m C j C j G c C c G j C j C g J c G g G c J c J c G j Jc C c G 2400 baud G c C g C m C j C j G c C c G j C j G g C g J c C g C c G m G j Jc C c G 300 baud...
  • Page 20 Enter configuration Exit & Save configuration RS232 DATA BITS 7 bits G c C g C m C j C j G c C c C j G j C g J c G g C j Jc G c G j Jc C c G 8 bits G c C g C m C j C j G c C c C j G j C g J g G c G j C c J c G j Jc C c G 9 bits...
  • Page 21 Enter configuration Exit & Save configuration RS232 RADIO RX LOCK disabled enabled See par. 3.1.2 for details. INTER-CHARACTER DELAY delay between characters transmitted to Host Read 2 numbers from the table where: G c C g C m C j C j G c C c G j Jc G g C c J g G j Jc C c G 00 = DELAY disabled 01-99 = DELAY from 1 to 99 milliseconds RX TIMEOUT...
  • Page 22: Wedge Parameters

    WEDGE PARAMETERS PARAMETERS DEFAULT KEYBOARD NATIONALITY CAPS LOCK NUM LOCK INTER-CHARACTER DELAY disabled INTER-CODE DELAY disabled CONTROL CHARACTER EMULATION Ctrl+Shift+Key TO CHANGE THE DEFAULT VALUES Read the Enter Configuration code ONCE, available at the top of each page. Read configuration codes from the desired groups = Choose only one code from each selected group = Follow the procedure given for this code group Read the Exit and Save Configuration code ONCE, available at the top of...
  • Page 23 Enter configuration Exit & Save configuration WEDGE KEYBOARD NATIONALITY NOTE When IBM AT - Alt Mode Interface is selected, it is not necessary to set the Keyboard Nationality. English G c C g C m C j G j C c C c G c J jG g C g J c C c C g M g G j Jc C c G French G c C g C m C j G j C c C c G c J jG g J g C c C m G g C c G j Jc C c G German...
  • Page 24 Enter configuration Exit & Save configuration WEDGE KEYBOARD NATIONALITY (continued) NOTE When IBM AT - Alt Mode Interface is selected, it is not necessary to set the Keyboard Nationality. Russian (Latin) G c C g C m C j G j C c C c G c J jJg C c G g C c M c C j G j Jc C c G Russian (Cyrillic) G c C g C m C j G j C c C c G c J jC c C j G j C g J c G g G j Jc C c G Hungarian...
  • Page 25 Enter configuration Exit & Save configuration WEDGE NUM LOCK Toggle Num lock G c C g C m C j G j C c C j G c J c C g J c G g C g G m C c G j Jc C c G Num lock unchanged use if Num lock key status is OFF G c C g C m C j G j C c C j G c J c C g J g G c G m C g C c G j Jc C c G...
  • Page 26 Enter configuration Exit & Save configuration WEDGE CONTROL CHARACTER EMULATION Ctrl + Shift + Key Ctrl + Key Web : http: www.audin.fr - Email : info@audin.fr...
  • Page 27: Pen Emulation Parameters

    PEN EMULATION PARAMETERS PARAMETERS DEFAULT OPERATING MODE interpret MINIMUM OUTPUT PULSE 600 µs CONVERSION TO CODE 39 AND CODE 128 code 39 OVERFLOW medium OUTPUT LEVEL normal IDLE LEVEL normal TO CHANGE THE DEFAULT VALUES Read the Enter Configuration code ONCE, available at the top of each page. Read configuration codes from the desired groups = Choose only one code from each selected group Read the Exit and Save Configuration code ONCE, available at the top of...
  • Page 28 PEN EMULATION The values of the operating mode parameter are complete commands and do not require reading the Enter and Exit configuration codes. OPERATING MODE interpret mode G c C g C m C g C j G g G g C m C c J c C g G g G j Jc C c G Interprets commands without sending them to the decoder.
  • Page 29 Enter configuration Exit & Save configuration PEN EMULATION MINIMUM OUTPUT PULSE high resolution code emulation 200 µ s G c C g C m C c G j C j G c C j C j C g J c G g J c M c C c G j Jc C c G 400 µ...
  • Page 30 Enter configuration Exit & Save configuration PEN EMULATION OVERFLOW narrow G c C g C m C c G j C j G j C c C j C g J c G g M jC c C c G j Jc C c G medium G c C g C m C c G j C j G j C c C j C g J g G c C g C c G m G j Jc C c G wide...
  • Page 31: Cradle Operating Parameters

    CRADLE OPERATING PARAMETERS PARAMETERS DEFAULT no header HEADER TERMINATOR RS232: CR-LF WEDGE: CR ADDRESS STAMPING disabled disabled ADDRESS DELIMITER TO CHANGE THE DEFAULT VALUES Read the Enter Configuration code ONCE, available at the top of each page. Read configuration codes from the desired groups = Choose only one code from each selected group = Follow the procedure given for this code group Read the Exit and Save Configuration code ONCE, available at the top of...
  • Page 32 Enter configuration Exit & Save configuration Cradle Operating Parameters HEADER no header G c C g C m C j G c C j C c C j G j C g J c G g C g J c G g G g C j C g G j Jc C c G one character header G c C g C m C j G c C j C c C j G j C g J c G g C g J g G c C g G g J c G j Jc C c G two character header...
  • Page 33 Enter configuration Exit & Save configuration Cradle Operating Parameters ADDRESS STAMPING Gun Address Stamping disabled G c C g C m G j C c C j G c J c J c C g J c G g C c C c M jG j Jc C c G Cradle Address Stamping disabled G c C g C m G j C c C j G c J c J c G g J g C c M c C j C c G j Jc C c G Gun Address Stamping enabled...
  • Page 34: Battery Charging

    BATTERY CHARGING PARAMETER DEFAULT OM6010-R BATTERY TYPE Auto-detect TO CHANGE THE DEFAULT VALUES Read the Enter Configuration code ONCE, available at the top of the page. Read configuration codes from the desired groups = Choose only one code from each selected group Read the Exit and Save Configuration code ONCE, available at the top of the page.
  • Page 35 Enter configuration Exit & Save configuration Battery Charging OM6010-R BATTERY TYPE auto-detect G c C g C m G j C c C j G c J jC c C g J c G g G c M c G c G j Jc C c G Alkaline G c C g C m G j C c C j G c J jC c C g J g G c C c C j Mc G j Jc C c G NiMh/NiCd...
  • Page 36: Network Parameters

    NETWORK PARAMETERS FOR MULTIDROP NETWORK SYSTEMS ONLY PARAMETER DEFAULT ECHELON FIELDBUS disabled TO CHANGE THE DEFAULT VALUES Read the Enter Configuration code ONCE, available at the top of the page. Read configuration codes from the desired groups = Choose only one code from each selected group Read the Exit and Save Configuration code ONCE, available at the top of the page.
  • Page 37 Enter configuration Exit & Save configuration Network Parameters ECHELON FIELDBUS disabled G c C g C m G j C c C j Jc C j G c C g J c G g C c M jC c G j Jc C c G Master G c C g C m G j C c C j Jc C j G c G g J g C c M c C c J c G j Jc C c G Slave...
  • Page 38 PARAMETERS Web : http: www.audin.fr - Email : info@audin.fr...
  • Page 39: Gun Operating Parameters

    GUN OPERATING PARAMETERS PARAMETERS DEFAULT ACK FROM HOST disabled RADIO TIMEOUT 1/2 sec. SET DATE AND TIME TIME STAMPING FORMAT disabled disabled TIME STAMPING DELIMITER disabled CODE IDENTIFIER TO CHANGE THE DEFAULT VALUES Read the Enter Configuration code ONCE, available at the top of each page. Read configuration codes from the desired groups = Choose only one code from each selected group = Follow the procedure given for this code group...
  • Page 40 Enter configuration Exit & Save configuration Gun Operating Parameters ACK FROM HOST disabled enabled For more details, see par. 3.4.1 RADIO TIMEOUT G c C g C m G j C c C j G j C c C j G g J g C c G j Jc C c G Read 3 numbers in the range 000-255: 000 = disables Radio Timeout (always on).
  • Page 41 Enter configuration Exit & Save configuration Gun Operating Parameters TIME STAMPING FORMAT disabled G c C g C m G j C c C j C j G c J c C g J c G g C m G g C c G j Jc C c G hour/minutes/seconds month/day/year G c C g C m G j C c C j C j G c J c C g J g G c M c J c C c G j Jc C c G...
  • Page 42 G c C g C m C j G c C j C j C c G j G g J g C c J c G c C j G j Jc C c G DATALOGIC standard G c C g C m C j G c C j C j C c G j C g J g G c J c C c G j G j Jc C c G For more details, see par.
  • Page 43: Reading Parameters

    READING PARAMETERS PARAMETERS DEFAULT level TRIGGER SIGNAL 10 sec. TRIGGER TIMEOUT READS PER CYCLE .5 sec. SAFETY TIME SINGLE-STORE disabled POWER-OFF TIMEOUT 8 hours GOOD TRANSMISSION BEEP enabled BEEPER INTENSITY high BEEPER TONE TO CHANGE THE DEFAULT VALUES Read the Enter Configuration code ONCE, available at the top of each page. Read configuration codes from the desired groups = Choose only one code from each selected group = Follow the procedure given for this code group...
  • Page 44 Enter configuration Exit & Save configuration Reading Parameters TRIGGER SIGNAL trigger active level G c C g C m C j C c G j C c C j G j C g J c G g C c J jG c G j Jc C c G trigger active pulse G c C g C m C j C c G j C c C j G j C g J g G c G c C j Jc G j Jc C c G See par.
  • Page 45 Enter configuration Exit & Save configuration Reading Parameters SINGLE-STORE disabled G c C g C m G j C c C j C j Jc G c G g J g C c M c C g C g G j Jc C c G enabled G c C g C m G j C c C j C j Jc G c G g C c J g G c G c M c G j Jc C c G See par.
  • Page 46 Enter configuration Exit & Save configuration Reading Parameters BEEPER INTENSITY beeper off G c C g C m C j C c G j G c C j C j C g J c G g J c G j C c G j Jc C c G low intensity G c C g C m C j C c G j G c C j C j C g J g G c G g C m C c G j Jc C c G medium intensity...
  • Page 47: Decoding Parameters

    DECODING PARAMETERS PARAMETERS DEFAULT INK SPREAD enabled OVERFLOW CONTROL enabled INTERDIGIT CONTROL enabled DECODING SAFETY one read CAUTION Before changing these parameter values read the descriptions in par. 3.6. TO CHANGE THE DEFAULT VALUES Read the Enter Configuration code ONCE, available at the top of each page. Read configuration codes from the desired groups = Choose only one code from each selected group Read the Exit and Save Configuration code ONCE, available at the top of...
  • Page 48 Enter configuration Exit & Save configuration Decoding Parameters INK-SPREAD disabled G c C g C m C c C j G j JjC c G c C g J c G g M c G c G c G j Jc C c G enabled G c C g C m C c C j G j JjC c G c C g J g G c C j C c M c G j Jc C c G See par.
  • Page 49 Enter configuration Exit & Save configuration Decoding Parameters DECODING SAFETY one read two reads (decoding safety disabled) three reads four reads Required number of good reads before accepting code. Web : http: www.audin.fr - Email : info@audin.fr...
  • Page 50: Gun Display Parameters

    GUN DISPLAY PARAMETERS PARAMETERS DEFAULT DISPLAY FONT SIZE small DISPLAY TIMEOUT 8 sec. DISPLAY BACKLIGHT normal DISPLAY CONTRAST normal DISPLAY MODE TO CHANGE THE DEFAULT VALUES Read the Enter Configuration code ONCE, available at the top of each page. Read configuration codes from the desired groups = Choose only one code from each selected group = Follow the procedure given for this code group Read the Exit and Save Configuration code ONCE, available at the top of...
  • Page 51 Enter configuration Exit & Save configuration Gun Display Parameters DISPLAY FONT SIZE small font (6 x 8) G c C g C m G j C c C j C c C j G j C g J c G g G c J jC c G j Jc C c G 16 x 4 characters on display medium font (8 x 8) G c C g C m G j C c C j C c C j G j C g J g G c J c C j G c G j Jc C c G...
  • Page 52 Enter configuration Exit & Save configuration Gun Display Parameters DISPLAY CONTRAST lighter G c C g C m G j C c C j C j Jc G c J c G c J c J c C c M c G j Jc C c G darker G c C g C m G j C c C j C j Jc G c G g J c C g M c C j C c G j Jc C c G Read the code until the desired contrast is reached.
  • Page 53: Code Selection

    CODE SELECTION PARAMETERS DEFAULT EAN 8/EAN13 UPC A/UPC E EAN/UPC FAMILY check digit transmitted no conversions Interleaved 2/5 2/5 FAMILY check digit control and transmission variable length code: 4-99 characters Standard Code 39 CODE 39 FAMILY no check digit control variable length code: 1-99 characters Code 128 CODE 128 FAMILY...
  • Page 54 Enter configuration Exit & Save configuration Code Selection DISABLES ALL CODE FAMILIES G c C g C m C c C j G j Jc G j C c C g J c G g C c M c C j G j Jc C c G NOTE The reader allows up to 5 code selections.
  • Page 55 Enter configuration Exit & Save configuration Code Selection EAN/UPC FAMILY disables the family G c C g C m C c C j G j C c C j G j C g J c G g C c J c G j G j Jc C c G Read a single code or combination code selection EAN 8 G c C g C m C c C j G j C c C j G j G g J g C c G c J c C j G j Jc C c G...
  • Page 56 Enter configuration Exit & Save configuration Code Selection EAN/UPC CHECK DIGIT TX SELECTIONS For each code type in this family you can choose to transmit the check digit or not EAN 8 G c C g C m C c C j G j C c C j G j G c C j C j G j C g C g G j Jc C c G EAN 13 G c C g C m C c C j G j C c C j G j G j C c C j C g G g J c G j Jc C c G check digit transmission...
  • Page 57 Enter configuration Exit & Save configuration Code Selection CONVERSION OPTIONS UPC E to UPC A conversion UPC E to EAN 13 conversion UPC A to EAN 13 conversion EAN 8 to EAN 13 conversion enable only ISBN conversion enable only ISSN conversion enable both ISBN and ISSN conversion disable both ISBN and ISSN conversion Web : http: www.audin.fr - Email : info@audin.fr...
  • Page 58 Enter configuration Exit & Save configuration Code Selection 2/5 FAMILY disables the family G c C g C m C c C j G j C j C j G c C g J c G g G c C j Jc G j Jc C c G Read a check digit selection Read the desired family code Interleaved 2/5...
  • Page 59 Enter configuration Exit & Save configuration Code Selection CODE 39 FAMILY disables the family G c C g C m C c C j G j C j C c G j C g J c G g C j Jc G c G j Jc C c G Read the desired family code The pharmaceutical codes below are part of the Code 39 family but have no check...
  • Page 60 Enter configuration Exit & Save configuration Code Selection CODE 128 FAMILY disables the family G c C g C m C c C j G j G j C j C c C g J c G g G g C m C c G j Jc C c G Code 128 G c C g C m C c C j G j G j C j C c C g J g G c C g J g G c J g G g C c G j Jc C c G EAN 128...
  • Page 61 Enter configuration Exit & Save configuration Code Selection ADD FIRST GS IN EAN 128 disabled enabled CODE 93 disables the code G c C g C m C c C j G j C c G j Jc C g J c G g C g C c G m G j Jc C c G Code 93 G c C g C m C c C j G j C c G j Jc C g J g G c C m C g G c G j Jc C c G control without transmission of check digit...
  • Page 62 Enter configuration Exit & Save configuration Code Selection CODABAR FAMILY disables the family G c C g C m C c C j G j C c G j C j C g J c G g G c J c C j G j Jc C c G For Standard Codabar: Read the desired equality control code Read a start/stop transmission selection...
  • Page 63: References

    REFERENCES 3 REFERENCES 3.1 RS232 PARAMETERS 3.1.1 Handshaking Hardware handshaking (RTS/CTS) Signals at The RTS line is activated EIA levels by the decoder before transmitting a character. Transmission is possible only if line Transmitted data Transmitted data (controlled by the Host) is active.
  • Page 64: Rx Timeout

    DLL6000-R/OM6010-R COMPATIBILITY disabled, where data can be collected only when communication is possible. In any case, prior to interruption, data is buffered in the cradle. This command is only effective if handshaking is enabled. If used in a Multidrop Network, it only works for the Master cradle. If disabled, guns continue to send data to the cradle which buffers them even if data communication has been interrupted by the Host (CTS low or XOFF).
  • Page 65: Pen Emulation Parameters

    REFERENCES 3.3 PEN EMULATION PARAMETERS 3.3.1 Minimum Output Pulse This parameter sets the duration of the output pulse corresponding to the narrowest element in the barcode. In this way the code resolution is controlled by the signal sent to the decoder, independently of the physical resolution of the code read.
  • Page 66: Output And Idle Levels

    DLL6000-R/OM6010-R COMPATIBILITY 3.3.3 Output and Idle Levels The following state diagrams describe the different output and idle level combinations for Pen emulation: idle OUTPUT: Normal black space IDLE: Normal white barcode output OUTPUT: Normal black idle IDLE: Inverted space white barcode output space OUTPUT: Inverted...
  • Page 67: Radio Timeout

    REFERENCES 3.4.2 Radio Timeout After a code has been read and transmitted, the radio remains active for the amount of time set by the Radio Timeout parameter. This is particularly useful when the Host is expected to send a reply message to the gun. This parameter depends heavily on the application and is therefore provided here for system optimization according to your application.
  • Page 68: Header/Terminator Selection

    DLL6000-R/OM6010-R COMPATIBILITY Header/Terminator Selection The header/terminator selection is not effected by the reading of the restore default code. In fact, header and terminator default values depend on the interface selection: RS232: no header, terminator CR-LF WEDGE: no header, terminator CR These default values are always restored through the reading of RS232 or WEDGE interface selection code, step 10 of the System Start Up procedure.
  • Page 69: Gun/Cradle Address Stamping

    REFERENCES Gun/Cradle Address Stamping It is possible to include the gun and cradle addresses in the message sent to the host. The Gun Address Stamping and the Cradle Address Stamping parameters consist of a 3-digit number in the range 000 to 126. For message output format, refer to the example on page 58.
  • Page 70: Code Identifier

    DLL6000-R/OM6010-R COMPATIBILITY Code Identifier CODE IDENTIFIER TABLE DATALOGIC CODE AIM STANDARD STANDARD 2/5 interleaved ] I y 2/5 industrial ] X y 2/5 normal 5 bars ] S y NOTE 2/5 matrix 3 bars ] X y EAN 8 ] E 4...
  • Page 71: Trigger Timeout

    REFERENCES 3.5.2 Trigger Timeout When this timeout is selected, the reader which is triggered ON but not decoding turns the laser OFF automatically after the desired period of time. 3.5.3 Reads per Cycle A reading cycle depends on the trigger signal selection (see par. 3.5.1) and on the trigger timeout selection (see par.
  • Page 72: Power-Off Timeout

    DLL6000-R/OM6010-R COMPATIBILITY Single-store may be useful if you often read codes at the limit of the coverage area and there is a chance that code transmission can fail. In such case single- store allows you to move to a more favorable position or location (i.e. closer to the cradle) and retry transmission without the necessity of re-reading the code since it is already stored in the gun.
  • Page 73: Overflow Control

    REFERENCES 3.6.2 Overflow Control The overflow control parameter can be disabled when decoding codes printed on small surfaces, which don’t allow the use of an overflow space. This command does not effect code families 2/5, Code 128 and Code 93. For the EAN/UPC code family, do not use code combinations.
  • Page 74: Software Release

    DLL6000-R/OM6010-R COMPATIBILITY Local Echo mode: When a barcode is read with the gun: • The code is sent to the Host. • The gun display is cleared. • The code is also sent to the gun display (Local Echo). • The cursor is positioned after the last printed character on the gun display.
  • Page 75: Communication And Message Formatting

    COMMUNICATION AND MESSAGE FORMATTING 4 COMMUNICATION AND MESSAGE FORMATTING The system always provides gun to host data communication using the message formatting described in par. 3.4.3. However, if the RS232 interface is selected for communication between the Host OM6010-R cradle, then following additional...
  • Page 76: Cursor Control

    DLL6000-R/OM6010-R COMPATIBILITY • If you want to control the gun's beeper from the host, you will also probably want to disable the good transmission beep that is emitted when the code is received from the cradle. (See command on page 37). The message field can store plain text and escape sequences.
  • Page 77: Font Selection

    COMMUNICATION AND MESSAGE FORMATTING 4.1.2 Font Selection Normal mode ESC [ 0 m ESC [ 7 m Reverse mode Large font: subsequent characters are written on the current row ESC # 4 and the row below it using the 12x16 font which allows for two rows of eight characters on the display.
  • Page 78: Led And Beeper Control

    DLL6000-R/OM6010-R COMPATIBILITY 4.1.4 LED and Beeper Control Emit short High tone + short delay ESC [ 0 q Emit short Low tone + short delay ESC [ 1 q Emit long Low tone + short delay ESC [ 2 q ESC [ 3 q Emit good read tone Emit bad tx tone...
  • Page 79: Messages From Gun Command Keys

    COMMUNICATION AND MESSAGE FORMATTING 4.2 MESSAGES FROM GUN COMMAND KEYS The DLL6000-R series guns with display have 3 command keys that can each be associated with a character to send to the host. By pressing the keys on the gun, the associated character with its relative message formatting is sent to the Host.
  • Page 80 DLL6000-R/OM6010-R COMPATIBILITY The Key Identifier values can be customized by using the configuration procedure below: Enter Configuration G c C g C m C g C j G g G j C g C g J c G g C g G j Jc C c G Key Identifier where: xx = left-key Identifier G c C g C m G j C c C j C c G j Jc C g J g G c G m C g C c G j Jc C c G...
  • Page 81: Host Configuration Strings

    HOST CONFIGURATION STRINGS APPENDIX A HOST CONFIGURATION STRINGS In this section we provide a description of how to modify the configuration using serial command strings sent from the Host. This method requires the RS232 interface. Command Carriage return character (0D Hex.) Exit and Save configuration Character sequence in following tables Enter configuration environment...
  • Page 82 DLL6000-R/OM6010-R COMPATIBILITY NOTE The buffer can contain a maximum of 256 characters. If your programming string goes over this value, you must split it into separate groups, according to the following rules: • all gun commands must reside in one single string; •...
  • Page 83 HOST CONFIGURATION STRINGS SERIAL CONFIGURATION STRINGS CONFIGURATION COMMANDS DESCRIPTION STRING Restore factory default configuration Transmit the Cradle Software release The above commands do not require $- to exit. Cradle Parameters INTERFACE SELECTION DESCRIPTION STRING RS232 interface PEN emulation interface WEDGE for IBM AT CP500 for IBM AT –...
  • Page 84 DLL6000-R/OM6010-R COMPATIBILITY WEDGE PARAMETERS DESCRIPTION STRING Keyboard Type for Typewriter IBM Terminals 31xx, 32xx,34xx, 37xx: Advanced Keyboard Nationality English French German Italian Swedish Spanish Belgian Japanese Russian (Latin) Russian (Cyrillic) Hungarian Yugoslavian Romanian Czechoslovakian Caps Lock Caps Lock ON Caps Lock OFF Num Lock Num Lock unchanged Toggle Num Lock...
  • Page 85 OM6010-R Battery selection Autodetect Alkaline battery NiMh or NiCd battery MULTIDROP NETWORK PARAMETERS DESCRIPTION STRING Echelon fieldbus Disabled Slave Master Gun Parameters GUN OPERATING PARAMETERS DESCRIPTION STRING Code Identifier Disabled Datalogic standard AIM standard Web : http: www.audin.fr - Email : info@audin.fr...
  • Page 86 DLL6000-R/OM6010-R COMPATIBILITY GUN OPERATING PARAMETERS (continued) DESCRIPTION STRING Time Stamping Format Disabled Hour/minutes/seconds/month/day/year Hour/minutes/seconds/day/month/year Hour/minutes/seconds Month/day/year Day/month/year Time Stamping Delimiter Disabled Select delimiter HM1 y ACK from Host Disabled Enabled Radio Timeout Tout (range is 000 to 255) HH000-HH255 Set Time HD hhmm Set Date HE ddmmyy...
  • Page 87 HOST CONFIGURATION STRINGS DECODING PARAMETERS DESCRIPTION STRING Ink-Spread Disabled Enabled Overflow Control Disabled Enabled Interdigit Control Disabled Enabled Decoding Safety One read Two reads Three reads Four reads GUN DISPLAY PARAMETERS DESCRIPTION STRING Display Font Size Small Medium Large Display Timeout HB00-HB99 Display Backlight Disabled...
  • Page 88 DLL6000-R/OM6010-R COMPATIBILITY CODE SELECTION DESCRIPTION STRING Disable ALL family codes EAN/UPC Disable EAN/UPC family EAN 8 EAN 13 UPC A UPC E EAN 8/EAN 13/UPC A/UPC E without ADD ON with ADD ON with and without ADD ON EAN 8/EAN 13 without ADD ON with ADD ON UPC A/UPC E...
  • Page 89 HOST CONFIGURATION STRINGS CODE SELECTION (continued) DESCRIPTION STRING Disable Code 2/5 family Interleaved 2/5 no check digit control AC11 xxxx (max code length 99) check digit control and transmission AC12 xxxx check digit control without transmission AC13 xxxx Normal 2/5 5 bars no check digit control AC21 xxxx (max code length 99)
  • Page 90: C6010 Configuration

    DLL6000-R/OM6010-R COMPATIBILITY APPENDIX B C6010 CONFIGURATION It is possible to configure the C6010 for the battery type to charge using any gun. Read one of the following labels: auto-detect G c C g C m C g C j G g G j C g C g G j C c C j C c J jG c G g C c J g C g C j G g C g G c J g J g C g G c G j Jc C c G Alkaline G c C g C m C g C j G g G j C g C g G j C c C j C c J jG c G g C g J c C g C j G g C g G c J g G c G j G c G j Jc C c G NiMh/NiCd...
  • Page 91: Hex And Numeric Table

    HEX AND NUMERIC TABLE APPENDIX C HEX AND NUMERIC TABLE OPEN THIS PAGE TO READ THE DESIRED HEX AND NUMERIC SELECTIONS Web : http: www.audin.fr - Email : info@audin.fr...
  • Page 92 HEX AND NUMERIC TABLE HEX / NUMERIC TABLE CHARACTER TO HEX CONVERSION TABLE char char char < > SPACE " & Backspace Cancels an incomplete configuration sequence Web : http: www.audin.fr - Email : info@audin.fr...
  • Page 93 90ACC1855 Web : http: www.audin.fr - Email : info@audin.fr...