Energy Rate Scale; Energy Total Units; Energy Total Scale - Siemens SITRANS F Instruction Manual

Ultrasonic flowmeters
Hide thumbs Also See for SITRANS F:
Table of Contents

Advertisement

Section 2
To select Energy Rate Units:
To access [Energy Rate Units] press
To move the cursor to the required units press
To store selection press

2.6.3 ENERGY RATE SCALE

The [Energy Rate Scale] menu cell shows the units (with the appropriate multiplier) that the energy/flow
computer selects for the energy rate display (e.g., MBTU/HR). The energy/flow computer's default scaling
selection is based on the pipe size and MAX Td entries that you select. This scaling applies to all energy
rate data displayed on the LCD Graphics Screen, even if the units do not appear next to the data when
there is not enough room on the screen. Therefore, always keep this prefix in mind when you enter
energy rate-related data.
To select a different Energy Display Scale:
To access the [Flow Display Scale] option list press
Move the cursor to the desired display scale by pressing
To register selection press

2.6.4 ENERGY TOTAL UNITS

FUE1010EN allows independent selection of energy rate and total units. The units you select in this
menu cell apply to the totaled thermal energy display on the Graphic Screen and to the Datalogger
reports that you generate. The Create Site command uses BTU for the system default. If this suits the
application, then you may bypass this menu cell by pressing the <Down Arrow>.
To select the Energy Total Unit:
To access the [Energy Total Units] option list press
To move the cursor to the required units press
To store your choice press

2.6.5 ENERGY TOTAL SCALE

The [Energy Total Scale] menu cell shows the units (with the appropriate multiplier) that the energy/flow
computer selects for the energy TOTAL display (e.g., BTU). The energy/flow computer's default scaling
selection is based on the pipe size and MAX Td entries that you select. This scaling applies to all energy
totalizer data displayed on the LCD Graphics Screen, even if the units do not appear next to data when
there is not enough room.
To select a different Energy Total Scale:
To access the [Energy Total Scale] option list press
ENT
ENT
ENT
2-38
1010ENFM-3B

Advertisement

Table of Contents
loading

Table of Contents