Repair
9. See F
. 19. Carefully place the bottom
IG
cover/piston assembly on the cylinder (205), sliding
the piston (219) into the cylinder. The manifold
surfaces of the top and bottom covers must align.
Be sure the shield (206) is in the groove on both the
top and bottom covers.
201
groove
206
groove
F
. 19. Align Shield in Grooves on Covers
IG
26
10. Install the tie bolts (212) hand tight.
11. Install two gaskets (208*) on the manifold (220).
Install the manifold (220). Torque screws (211) to
95-105 in-lb (10.7-11.9 N•m).
NOTE: The manifold is reversible for ease of placement
of muffler or remote exhaust.
12. Align the air valve gasket (209*◆†) on the manifold,
then attach the air valve (214). Torque screws (211)
to 95-105 in-lb (11-12 N•m).
13. Tighten the tie bolts (212) halfway. Work in a
crisscross pattern. Check that the shield (206)
remains in the grooves on both covers. Continue
tightening the bolts in pattern to 11-13 ft-lb (15-18
N•m).
14. On 3.5 in. motors only, lubricate the o-ring (230*).
Install it and the plug (231) in the top cover (210).
15. Lubricate and install pilot valves (213) in top and
bottom cover. Torque to 95-105 in-lb (11-12 N•m).
210
16. See Reconnect the Air Motor on page 23.