1.
Before Setting Up Your
Projector
1.1

Lamp Power Supply Installation Conditions

The location where you install the lamp power supply must have a plenty of space in front of the
air inlet and air outlet to prevent the inside of that unit from becoming excessively hot. Ensure
that air can flow inside the unit to allow the internal cooling. Be careful of the following points
when setting up the lamp power supply.
When the lamp power supply is not
stored in a rack or case:
When the lamp power supply is
stored in a rack or case:
Pedestal
Air outlet
(duct structure) (NC-32PS01)
Air inlet
(NC-32PS02)
Lay out the lamp power supply so that a sufficient space is assured around it.
- Space in front of the air inlet (guide): 20 cm at least
- Space in front of the air outlet (guide): 50 cm at least
Ensure a plenty of case opening area on the portions facing the air inlet and the air
outlet of the lamp power supply.
- Air inlet opening area: 36000 mm
- Air outlet opening area: 48400 mm
A duct structure should be configured to lead to the air outlet on the rack or case so
that the exhaust from the lamp power supply can be exhausted.
This is to ensure that the air does not circulate only inside the rack or case.
Lay out the rack or case storing the lamp power supply so that a sufficient space is
assured around them.
- Space in front of the air inlet (guide): 20 cm at least
- Space in front of the air outlet (guide): 50 cm at least
2
at least
2
at least, duct structure
Air inlet
(NC-32PS01)
Air outlet
(duct structure) (NC-32PS02)
Lamp Power
Supply