Colour Digital Display:
Ambient Humidity
<45%,
45≤Ambient Humidity
Ambient Humidity
>65%
If the LED display E0、E2、CL、CH、LO、HI, the light will show red.
E2
Humidity sensor problem - Change a sensor
LO
Environmental humidity is below 20% - The dehumidifier shuts down for self-
protection
HI
Environmental humidity is above 90% - The dehumidifier shuts down for self-
protection
CL
Low temperature protection, the environmental temperature<5℃ - The dehumidifier
shuts down for self- protection
CH
High temperature protection, the environmental temperature>38℃ - The
dehumidifier shuts down for self- protection
Page | 13 For enquiries or support : visit www.gmcaircon.co.za or contact us on +27 12 661 1173